52

Flat Field Control Feature Description

The follow ing table d escribes these p aram eters along w ith their view attribu te and m inim u m cam era
firm w are version requ ired . Ad d itionally the firm w are colu m n w ill ind icate w hich p aram eter is a
m em ber of the DALSA Featu res N am ing Convention (DFN C), verses the GenICam Stand ard Featu res
N am ing Convention (SFN C not show n).
The Device Version nu m ber rep resents the cam era softw are fu nctional grou p , not a firm w are revision
nu m ber.
Display Name
Mod e
Off
On
Initialize
Calibration Algorithm
Basic
Low Pass
Calibration Target
Calibration Sam p le Size
Lines_2048
Lines_4096
ROI Offset X
ROI Wid th
03-032-20206-00
Feature
flatfield CorrectionMod e
Off
On
Initialize
flatfield CorrectionAlgorithm
Basic
Low Pass
flatfield CalibrationTarget
flatfield CalibrationSam p leSize
Lines_2048
Lines_4096
flatfield CalibrationROIOffsetX
flatfield CalibrationROIWid th
Linea 2K and 4K Monochrome Line Scan Camera User's Manual
Description
FPN and flat field coefficients
d isabled .
FPN and flat field coefficients
enabled .
Reset all FPN to 0 and all flat field
coefficients to 1.
Selection betw een tw o d ifferent
flat field algorithm s.
Direct calcu lation of coefficients
based on average line valu es and
target. First each color is flat
field ed to its p eak valu e an d then
the color gains are u sed to achieve
the target.
A low p ass filter is first ap p lied to
the average line valu es before
calcu lating the coefficients. Use
this algorithm if the calibration
target is not u niform ly w hite or it
is not p ossible to d efocu s th e
im age. Becau se of the low p ass
filter this algorithm is not able to
correct p ixel-to-p ixel variations
and so it is p referable to u se the
―Basic‖ algorithm .
Set a valu e betw een 0 and 255 to
w hich the flat field algorithm w ill
taget the im age to.
Sets the nu m ber of lines to be
averaged d u ring a flat field
calibration
Set the starting p oint of a region
of interest w here a flat field
calibration w ill be p erform ed
Sets the w id th of the region on
interest w here a flat field
calibration w ill be p erform ed
Device
Version
& View
1.00
Beginner
DFN C
1.00
Beginner
DFN C
1.00
Beginner
DFN C
1.00
Beginner
DFN C
1.00
Beginner
DFN C
1.00
Beginner
DFN C
Teledyne DALSA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dalsa linea 2k clDalsa linea 4k cl