Gas dsi/electric/steam
Table of Contents

Advertisement

6. Failed hi-limit thermostat (for Electric Models Only).
7. Extractors (washers) are not performing properly.
8. Low and/or inconsistent gas pressure (for Gas Models Only).
9. Gas supply may have low heating value (for Gas Models Only).
10. Sail switch is fluttering (for Gas and Electric Models Only)...
a. Restriction in location exhaust system.
11. Fault in electric oven element circuit (for Electric Models Only)...
a. Failed element(s).
b. Failed oven contactor (relay).
12. Exceptionally cold/humid or low barometric pressure atmosphere.
13. Blower (squirrel cage fan) motor rotation direction is incorrect.
I.
Dryer is cycling on or tripping hi-limit thermostat (for Gas and Electric Models ONLY)...
1. Blower (squirrel cage fan) motor failure.
2. Blower (squirrel cage fan) motor rotation direction is incorrect.
3. Insufficient make-up air.
4. Restriction in location exhaust system...
a. Undersized exhaust ducting.
5. Lint screen needs cleaning.
6. Failed hi-limit thermostat.
7. Failed oven contactor (relay) (for Electric Models Only).