Continental Girbau CG50-60 Installation Manual page 29

Gas dsi/electric/steam
Table of Contents

Advertisement

CG50-60 (GAS/STEAM )
GAS/STEAM ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.
NOTES: A.
For others, calculate/verify correct breaker size according to appliance amp
draw rating and type of breaker to be used.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
B.
SERVICE
PHASE
VOLTAGE
120
208
240
208
240
380-400
416
460/480
IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact
Continental Girbau, Inc.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the upper left side panel area behind the top control (access) door. In the
case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: The manufacturer reserves the right to make changes in specifications at any time without
notice or obligation.
WIRE
SERVICE
2
2
2
3/4
3
3/4
3/4
3/4
®
APPROX. AMP DRAW
60 Hz
50 Hz
12
7.3
6.5
2.9
3.2
-
-
2.1
25
CIRCUIT
BREAKER
AMPERAGE
-
20
-
15
4.2
15
-
15
3.5
15
2.2
15
2.3
15
-
15

Hide quick links: