Continental Girbau CG50-60 Installation Manual page 56

Gas dsi/electric/steam
Table of Contents

Advertisement

ELECTRIC MODELS ONLY
1. Fault in sail switch circuit...
a. Sail switch is out of adjustment and/or failed.
b. Sail switch is not closing or fluttering...
1) Check blower (squirrel cage fan) motor and rotation direction.
2) Restriction in location exhaust system.
2. Failed oven hi-limit circuit.
3. Tripped lint compartment manual reset (225º F [107º C]) safety thermostat circuit.
4. Failed oven contactor/relay.
5. Failed heat selector switch.
STEAM MODELS ONLY
1. Steam damper binding and/or stuck.
2. Tripped lint compartment manual reset (225º F [107º C]) safety thermostat circuit.
3. Failed heat selector switch.
G. Heat unit is not operating for ONLY one (1) temperature selection...
1. Failed thermostat corresponding to selection made.
2. Failed heat selector switch.
H. Dryer operates but is taking too long to dry load...
1. Heating unit cycling on hi-limit thermostat (for Electric Models Only).
2. Steam damper binding in partially open position (for Steam Models Only).
3. Lint and/or dust accumulation on steam coil fins (for Steam Models Only).
4. Housekeeping...
a. Lint screen and lint compartment are not being cleaned on a regular basis.
b. Lint accumulation in location exhaust system.
5. Insufficient make-up air.