Co Ringing Types; Did Ringing - Panasonic DBS-576 Manual

Section 700 feature operation
Hide thumbs Also See for DBS-576:
Table of Contents

Advertisement

Chapter 3. System Features
settings. Up to eight Station Timer Classes may be specified. Then an extension may be assigned a
Station Timer Class.
The following table shows the extension timers that may be assigned on a class basis.
Table 6.
Station Timer Class
Number
1
Hold Recall Timer (KTEL)
2
Hold Recall Timer (SLT)
3
Transfer Recall Timer (KTEL and SLT)
4
Hold/Transfer Recall Ringing Timer
5
Call Park Recall Timer
6
Call Forward No Answer Timer (Day 1)
7
Call Forward No Answer Timer (Day 2)
8
Call Forward No Answer Timer (Night)
9
Floating Hold Recall Timer
Hardware Requirements
N/A
Related Programming
FF1-1-05: Station Timer Class Definitions
FF3-0 (Extensions): Station Timer Class Assignments
Considerations
N/A

CO Ringing Types

Description
Several types of CO ringing are available for the System including the following:
Direct Inward Dialing (DID) Ringing
Direct In Line (DIL) Ringing
Direct Inward System Access (DISA) Ringing
Multiple Ringing
These ringing types may be used in any combination in the System.

DID Ringing

DID Ringing allows calls on a common CO to be directed to ring to a specific extension or group of
extensions, etc. based upon the final digits dialed. These final digits are received from the DID trunk
and compared to a DID Table that determines where the calls should ring. Depending on the
assignments in the DID Table, names or trunk numbers are displayed. (Names can be up to 10 digits
long.)
34
Station Timer
DBS 576 (USA), issued March 1999
Section 700 - Operation
576-25-700

Advertisement

Table of Contents
loading

Table of Contents