TROUBLE SHOOTING GUIDE
HEATER ASSEMBLY
Problem
Probable Cause
Solution
Service Manual Reference
Problem
Probable Cause
Solution
Service Manual Reference
Heater is not turning off.
Defective switch or loose wiring or defective heater
assembly.
Check all wiring for loose wiring connections,
repair/replace as necessary. If all wiring connections
are suitable check heater on/off switch & heater
assembly for proper operation. Replace as
necessary.
Heater on/off switch Page 10
Heater assembly Page 11
Heater fan runs continuously.
Normal operation or loose wiring or defective switch
or defective heater assembly.
Normal operation is when the heater fan runs when
the heater switch is in the ON position. If the heater
runs when the switch is in the OFF position check all
wiring for loose connections, repair/replace as
necessary. If all wiring connections are suitable check
heater on/off switch & heater assembly for proper
operation. Replace as necessary.
Operation Page 3
Heater on/off switch Page 10
Heater assembly Page 11