Dvc-35Ip Intermittent Pilot Lighting Instructions - Empire Heating Systems DVC-35-1SPP Installation Instructions And Owner's Manual

Fan type direct vent wall furnace
Hide thumbs Also See for DVC-35-1SPP:
Table of Contents

Advertisement

DVC-35IP INTERMITTENT PILOT LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
A. This appliance is equipped with an ignition device
which automatically lights the pilot.
Do not try to light the pilot by hand.
B. BEFORE OPERATING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
1. STOP! Read the safety information above.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition device
which automatically lights the pilot. Do not try to
light the pilot by hand.
G AS FLOW
HONEYWELL IP SMART VALVE
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service
is to be performed.
3. Remove front panel door.
Page 12
causing property damage, personal injury or loss of life.
OPERATING INSTRUCTIONS
G AS VALVE SHOWN IN OFF POSITION
TO TURN OFF GAS TO APPLIANCE
• If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to slide the gas control knob.
Never use tools. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the appliance and to replace any part
of the control system and any gas control which has
been under water.
5. Remove front panel door.
6. Slide gas control switch to "OFF."
7. Wait ten (10) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas, STOP! Follow "B" in the safety information
above. If you don't smell gas, go to the next step.
8. Slide gas control switch to "ON".
9. Replace front panel door.
10. Turn on all electric power to the appliance.
11. Set thermostat to desired setting.
12. If the appliance will not operate, follow the instruc-
tions "TO TURN OFF GAS TO APPLIANCE" and
call your service technician or gas supplier.
4. Slide gas control switch to "OFF."
5. Replace front panel door.
12430-3-0903