This appliance may be installed in an aftermarket,
permanently located manufactured home (USA only)
or mobile home, where not prohibited by state or lo-
cal codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
WARNING: If not installed, operated and main-
tained in accordance with the manufacturer's in-
structions, this product could expose you to substanc-
es in fuel or from fuel combustion which can cause
death or serious illness.

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
AND
FAN TYPE
DIRECT VENT
WALL FURNACE
MODEL
DVC-35-1SPP
DVC-35-1IP
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
If you cannot reach your gas supplier, call
the fire department.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Heating Systems DVC-35-1SPP

  • Page 1: Installation Instructions

    OWNER’S MANUAL FAN TYPE DIRECT VENT WALL FURNACE MODEL DVC-35-1SPP DVC-35-1IP WARNING: If the information in these instruc- tions are not followed exactly, a fire or explosion Installer: Leave this manual with the appli- may result causing property damage, personal ance.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ....................3 Safety Information for Users of LP Gas .................4 Requirements for Massachusetts ....................5 Introduction ..........................6 Specifications .........................6 Gas Supply ......................... 7-8 Clearances ..........................8 Installation Instructions ....................9-11 DVC-35SPP Standing Pilot Lighting Instructions ...............12 DVC-35IP Intermittent Pilot Lighting Instructions ..............13 Pilot Flame Characteristics ....................14 Main Burner Flame Characteristics ..................15...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures, the appliance should be located • DO NOT put anything around the furnace that will ob- out of traffic and away from furniture and draperies. struct the flow of combustion and ventilation air.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday, and explosions. In its natural state, propane is odorless and when there may not be a minute to lose, everyone’s safety colorless.
  • Page 5: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment 3. SIGNAGE. A metal or plastic identification plate shall be installed in every dwelling, building or structure used in permanently mounted to the exterior of the building at a whole or in part for residential purposes, including those minimum height of eight (8) feet above grade directly in owned or operated by the Commonwealth and where the...
  • Page 6: Introduction

    INTRODUCTION Introduction Installation in Residential Garages Always consult your local Building Department regarding regulations, Gas utilization equipment in residential garages shall be installed so codes or ordinances which apply to the installation of a direct vent wall that all burners and burner ignition devices are located not less than 18” furnace.
  • Page 7: Gas Supply

    GAS SUPPLY Locating Gas Supply A manual main gas cock should be located in the vicinity of the The gas line can enter the unit either through the floor or outside unit. Where none exists, or where its size or location is not ad- wall.
  • Page 8: Clearances

    Checking Manifold Pressure Both Propane and Natural gas valves have a built-in pressure reg- TOP VIEW OF VALVE ulator in the gas valve. Natural gas models will have a manifold pressure of approximately 4.0” w.c. (.996kPa) at the valve outlet PRESSURE REGULATOR VENT with the inlet pressure to the valve from a minimum of 5.0”...
  • Page 9: Installation Instructions

    INSTALLATION INSTRUCTIONS Locating Wall Opening the louvers positioned for the desired discharge direction and The furnace is to be located on an outside wall. Locate wall studs mark the mounting holes using the register as a template. so that wall opening will be located between wall studs. The fur- 8.
  • Page 10 Locating Electric Supply diameter air inlet tube from collar of air drop assembly. A 7/8” (22mm) diameter knockout is provided at the bottom of 2. Attach 4” (102mm) diameter flue outlet tube onto flue outlet the left and right side panels. A three-prong (grounding) plug as- collar on combustion chamber.
  • Page 11 INSTALLATION INSTRUCTIONS (continued) Vinyl siding kit, DV-822, is available from Empire Comfort Sys- Reassembly and Resealing Vent-Air Intake System tems, Inc. The depth is 3” (76mm), which enables the vent cap to When vent-air intake system is removed for servicing the furnace, be extended away from siding or projections.
  • Page 12: Dvc-35Spp Standing Pilot Lighting Instructions

    DVC-35 SPP STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by •If you cannot reach your gas supplier, call the fire hand.
  • Page 13: Dvc-35Ip Intermittent Pilot Lighting Instructions

    DVC-35IP INTERMITTENT PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. T h i s a p p l i a n c e i s e q u i p p e d w i t h a n i g n i- •...
  • Page 14: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS The correct pilot flame (Figure 11) will be blue, extending past THERMOCOUPLE the thermocouple. The flame will surround the thermocouple just below the tip. Natural gas pilots require adjusting when the inlet gas pressure is above 5” w.c. (1.245kPa). Remove the pilot cover screw on the BURNER control valve (Figure 3), and turn the adjustment screw clockwise to reduce flame.
  • Page 15: Main Burner Flame Characteristics

    MAIN BURNER FLAME CHARACTERISTICS The correct flame will be a short, blue inner flame with a much larger, light blue, outer flame. The burner does not have a primary air adjustment. The flame will be correct if the factory-set pressure and orifice opening are used.
  • Page 16: Wiring

    PRESSURE REGULATOR ADJUSTMENT-UNDER CAP SCREW OUTLET PRESSURE TAP INLET PRESSURE TAP PILOT ADJUSTMENT- UNDER CAP SCREW GAS FLOW PILOT OUTLET IGNITOR-PILOT ASSY. WIRING TO 24 V. THERMOSAT TO 24 V. COMMON ON TRANSFORMER TO 24 V. “HOT” ON TRANSFORMER IP-MODEL GAS VALVE AND WIRING L1 “HOT”...
  • Page 17: Service And Maintenance Suggestions

    SERVICE AND MAINTENANCE SUGGESTIONS If Pilot Does Not Remain On After Releasing Knob: GENERAL: All furnaces have been fire-tested to check for proper 1. Follow instructions and hold button down longer and hard- operation. This includes, main burner flame, pilot flame, fan opera- tion, fan control, limit control and automatic valve operation.
  • Page 18: Dvc-35Ip Intermittent Pilot Sequence Of Operation

    DVC-35IP INTERMITTENT PILOT SEQUENCE OF OPERATION Apply 24 VAC START To Appliance Thermostat Calls for Heat 5 Minute Retry Delay Pilot Valve Ignition OFF  Flame Signal Wait for Flame Signal to  Detected Disappear System Check Internal Check Trial for Pilot Valve Opens ...
  • Page 19: Dvc-35Ip Intermittent Pilot System Troubleshooting Sequence

    DVC-35IP INTERMITTENT PILOT SYSTEM TROUBLESHOOTING SEQUENCE START IP SYSTEM TROUBLESHOOTING SEQUENCE Turn OFF Gas Supply Disconnect System Control SmartValve System Troubleshooting Sequence End View INSET A 24 Volt Harness of Control Note: Before Troubleshooting, Become Familiar Thermostat Harness Set Thermostat to Call for with the Sequence of Operation Connector Heat...
  • Page 20: How To Order Repair Parts

    HOW TO ORDER REPAIR PARTS Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your equipment.
  • Page 21: Parts View

    PARTS VIEW 12430-11-1008 Page 21...
  • Page 22: Service Notes

    SERVICE NOTES Page 22 12430-11-1008...
  • Page 23: Service Notes

    SERVICE NOTES 12430-11-1008 Page 23...
  • Page 24 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. Comfort Systems www.empirecomfort.com Page 24 12430-11-1008...

This manual is also suitable for:

Dvc-35-1ip

Table of Contents