Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
state or local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certified kit is used.
WARNING: If not installed, operated and
maintained in accordance with the manufactur-
er's instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL
AND
FAN TYPE
DIRECT VENT
WALL FURNACE
MODEL
DV-55T-1
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DV-55T-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Empire Heating Systems DV-55T-1

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS OWNER'S MANUAL FAN TYPE DIRECT VENT WALL FURNACE MODEL DV-55T-1 Installer: Leave this manual with the appli- ance. WARNING: If the information in these instruc- Consumer: Retain this manual for future refer- tions are not followed exactly, a fire or explosion ence.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ........................3 Vent Kit Information ............................3 Safety Information for Users of LP Gas ......................4 Requirements for Massachusetts ........................5 Introduction ..............................6 Specifications ...............................6 Gas Supply ............................... 7-8 Clearances ..............................8 Installation Instructions .......................... 9-11 Lighting Instructions ..........................12 Pilot Flame Characteristics ........................13 Main Burner Flame Characteristics ......................13 Wiring ................................14...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. excessive lint from carpeting, bedding materials, etc. It • Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies. is imperative that control compartments, burners and circulating air passageways of the appliance be kept •...
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday when and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone's safety will depend colorless.
  • Page 5: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment 3. SIGNAGE. A metal or plastic identification plate shall be installed in every dwelling, building or structure used in permanently mounted to the exterior of the building at a whole or in part for residential purposes, including those minimum height of eight (8) feet above grade directly in owned or operated by the Commonwealth and where the...
  • Page 6: Introduction

    INTRODUCTION Introduction Such equipment shall be located, or protected, so it is not subject to physi- Always consult your local Building Department regarding regulations, cal damage by a moving vehicle. codes or ordinances which apply to the installation of a direct vent wall Qualified Installing Agency furnace.
  • Page 7: Gas Supply

    GAS SUPPLY Locating Gas Supply A manual main gas cock should be located in the vicinity of The gas line can enter the unit either through the floor or outside the unit. Where none exists, or where its size or location is not wall.
  • Page 8: Clearances

    Checking Manifold Pressure Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold pressure of approximately 4.0" w.c. at the valve outlet with the inlet pressure to the valve from a minimum of 6.0" w.c. for the purpose of input adjustment to a maximum of 7.0"...
  • Page 9: Installation Instructions

    INSTALLATION INSTRUCTIONS Locating Wall Opening The furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. The furnace is 16 inches in width and normal 16 inches on center studs will not allow the furnace to be recessed into the wall unless a stud is repositioned.
  • Page 10 Using Plastic Expansion Anchors 1. After locating mounting holes, drill two (2) 5/16" diameter holes into the wall. 2. Insert two (2) plastic expansion anchors provided into the holes. 3. Tighten two (2) 10 x 1" screws provided into the plastic expansion anchors.
  • Page 11: Installation Instructions

    INSTALLATION INSTRUCTIONS (continued) Warning: When vinyl siding vent kit, DV-822 or 2" x 4" 1. Remove old caulking beneath the collar of the outside mounting framing is added to an existing installation (furnace is plate. Apply new caulking beneath the collar of the outside installed) do not attempt to add sections of pipe to the flue mounting plate.
  • Page 12: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by •...
  • Page 13: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS The correct pilot flame (Figure 12) will be blue, extending past PROPER FLAME ADJUSTMENT the thermocouple. The flame will surround the thermocouple just below the tip. Natural gas pilots require adjusting when the inlet gas pressure is above 5"...
  • Page 14: Wiring

    WIRING The appliance, when installed, must be electrically grounded in ac- cordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 15: Service And Maintenance Suggestions

    Pilot Outage During Normal Operation: Check air inlet tube for a good tight fit at both ends (6" The Service Department at Empire Comfort Systems, Inc. may diameter tube). be contacted to assist in servicing furnace or call a qualified Check burner door and pilot hole cover for tight seal.
  • Page 16: How To Order Repair Parts

    Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. Shipments contingent upon strikes, fires and all causes beyond our control. Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, IL 62220-2623 PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.
  • Page 17: Parts View

    PARTS VIEW 13118-7-0408 Page 17...