Empire Heating Systems DV-25-2SG Installation Instructions And Owner's Manual

Empire Heating Systems DV-25-2SG Installation Instructions And Owner's Manual

Direct vent wall furnace

Advertisement

Installer: Leave these instructions with the
consumer.
Consumer: Retain these instructions for future
use.
WARNING: If the information in this manual
is not followed exactly, a fire or explosion may
result causing property damage, personal injury
or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
12434-7-0706
INSTALLATION INSTRUCTIONS
OWNER'S MANUAL
AND
DIRECT VENT
WALL FURNACE
MODELS
DV-25-2SG
DV-35-2SG
EFFECTIVE DATE
JULY 2006
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
state or local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certified kit is used.
WARNING: If not installed, operated and
maintained in accordance with the manufacturer's
instructions, this product could expose you to
substances in fuel or from fuel combustion which
can cause death or serious illness.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Heating Systems DV-25-2SG

  • Page 1 INSTALLATION INSTRUCTIONS OWNER'S MANUAL DIRECT VENT WALL FURNACE MODELS DV-25-2SG DV-35-2SG Installer: Leave these instructions with the consumer. Consumer: Retain these instructions for future EFFECTIVE DATE use. JULY 2006 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ........................3 Safety Information for Users of LP Gas ......................4 Requirments for Massachusetts ........................5 Introduction ..............................6 Specifications ...............................6 Gas Supply ..............................7 Clearances ..............................8 Installation Instructions .......................... 8-10 Thermostat Location ..........................10 Lighting Instructions ..........................11 Pilot Flame Characteristics ........................12 Main Burner Flame Characteristics ......................12 Maintenance ...............................13...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures the appliance should be located circulating air passageways of the appliance be kept out of traffic and away from furniture and draperies. clean.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMTAION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday and explosions. In its natural state, propane is odorless and when there may not be a minute to lose, everyone's safety colorless.
  • Page 5: Requirments For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment 3. SIGNAGE. A metal or plastic identification plate shall be installed in every dwelling, building or structure used in permanently mounted to the exterior of the building at a whole or in part for residential purposes, including those minimum height of eight (8) feet above grade directly in owned or operated by the Commonwealth and where the...
  • Page 6: Introduction

    INTRODUCTION Introduction Gas utilization equipment in residential garages shall be installed Always consult your local Building Department regarding so that all burners and burner ignition devices are located not less regulations, codes or ordinances which apply to the installation of than 18"...
  • Page 7: Gas Supply

    GAS SUPPLY Locating Gas Supply Compounds used on threaded joints of gas piping shall be resistant to the The gas line can enter the unit either through the floor or outside wall. action of liquefied petroleum gases. The gas lines must be checked for The gas line opening should be made at this time.
  • Page 8: Clearances

    CLEARANCES 1. In selecting a location for installation, it is necessary to provide The vent terminal of a direct vent appliance, with an input of 50,000 adequate accessibility clearances for servicing and proper (14.6 KW) BTU per hour or less shall be located at least 9" (229mm) installation.
  • Page 9 INSTALLATION INSTRUTIONS (continued) outlet collar on combustion chamber. Attach vent cap into the On solid wall, when using wall studs for attachment of wall mounting 4"(102mm) diameter flue outlet tube. Attach vent cap to outside bracket, fasten wall mounting bracket to wall studs with (2) #10 x mounting plate with (3) #10 x 1/2"...
  • Page 10: Thermostat Location

    cap extension should not exceed a total depth of 13" (330mm) for DV-25 and DV-35. (See Figure 5a) Warning: When vinyl siding vent kit, DV-822 or 2" x 4" (51mm x 102mm) framing is added to an existing installation (furnace is installed) do not attempt to add sections of pipe to the flue outlet tube or air inlet tube.
  • Page 11: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. department.
  • Page 12: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS The correct flame will be almost horizontal, blue and will extend past the thermopile 1/4" (6mm). The flame will surround the thermopile just below the tip. On propane (LP-gas) slight yellow might occur where the pilot flame and burner flame meet. Natural gas pilots require adjusting when the inlet pressure is above 5"...
  • Page 13: Maintenance

    MAINTENANCE Cleaning Pilot Orifice Removing Main Burner After use, cleaning of the pilot burner may be required for the proper 1. Disconnect the thermopile and pilot supply line at the pilot flame. Also, cleaning of the pilot burner may be required due to burner.
  • Page 14: How To Order Repair Parts

    HOW TO ORDER REPAIR PARTS Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your equipment.
  • Page 15: Parts View

    PARTS VIEW Page 15 12434-7-0706...
  • Page 16: Optional Blower Installation Instructions

    OPTIONAL BLOWER INSTALLATION INSTRUCTIONS OPTIONAL BLOWER DRB-1 Vented Room Heaters RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) Direct Vent Wall Furnaces DV-25-(1, 2)SG and DV-35-(1, 2)SG Installing Optional DRB-1 Blower accordance with local codes or, in the absence of local codes, with 1.
  • Page 17 OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (continued) Cleaning The blower wheel will collect lint and could require cleaning once a year. If the air output decreases or the noise level increases, it indicates a dirty wheel. Complete removal of the wheel and scrubbing it with a brush under flowing water is recommended.
  • Page 18: Service Notes

    SERVICE NOTES Page 18 12434-7-0706...
  • Page 19 SERVICE NOTES Page 19 12434-7-0706...
  • Page 20 Empire Comfort Systems, Inc. 918 Freeburg Ave. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 FAX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www.empirecomfort.com Page 20 12434-7-0706...