READ AND SAVE THESE INSTRUCTIONS
WARRANTY
CANARM Ltd. warrants every new fan to be free of defects in material and workmanship, to the extent
that, within a period of one year from the date of purchase CANARM Ltd. shall either repair or replace
at CANARM's option, any unit or part thereof, returned freight prepaid, and found to be defective.
This warranty does not include any labour or transportation costs incidental to the removal and
reinstallation of the unit at the user's premises.
Components repaired or replaced are warranted through the remainder of the original warranty
period only.
This warranty applies to the original purchaser-user only; it is null and void in case of alteration,
accident, abuse, neglect, and operation not in accordance with instructions.
NOTICE: No warranty claims will be honored by CANARM Ltd. unless prior authorization is obtained.
Installation or Product problems? Do not return to store of purchase.
Contact Canarm Service at 1-800-265-1833 (CANADA) 1-800-267-4427 (U.S.A.)
1-800-567-2513 (EN FRANCAIS) Monday to Friday 8:00 - 5:00pm e.s.t.
M0017 - Rev. 5 - Rev Date: 22/04/03
Page 1 of 5

Advertisement

Table of Contents
loading

Summary of Contents for Canarm PLF09

  • Page 1 CANARM Ltd. warrants every new fan to be free of defects in material and workmanship, to the extent that, within a period of one year from the date of purchase CANARM Ltd. shall either repair or replace at CANARM’s option, any unit or part thereof, returned freight prepaid, and found to be defective.
  • Page 2: Installation

    Tighten the turn clips with a Phillips screw driver and a 3/8" socket wrench. (see Figure 1-b). PLF09 to PLF24 Models Simply remove the fan from the carton and proceed to next section.
  • Page 3: Electrical Connections

    ELECTRICAL CONNECTIONS If your fan is not provided with a cord, use the following procedure to wire the fan. WARNING WARNING: BE SURE POWER IS OFF AT THE ELECTRICAL PANEL BEFORE High Voltage, disconnect power before servicing. When bringing power to the fan, water-tight cable and connectors should be used. The cable will be brought to the motor through the slot provided in the top of the shutter and allowances in length of cable should be considered.
  • Page 4: Operation

    Varying a single speed fan will cause the motor to fail. Fan labels should indicate whether or not fan is variable speed. If unsure contact a Canarm representative with the fan model number at our head office.
  • Page 5: Replacement Parts

    See attached appendices for replacement parts. ACCESSORIES Canarm provides a full line of controls from simple on/off thermostats to sophisticated multiple staging controllers and PC based controllers. Winter covers are available for colder climates where the fan is shut down for the winter.
  • Page 6 14" Direct Drive Component Qty. Description G1028 Turn Clip G1050 PLF Mount Arm Link Bracket G1051-14 PLF Motor Arm G1910-14 14" Fan Guard G2809-14B PLF Housing G2900-14 14" Shutter Assembly G2950-14 14" 3/45 Rotair Blade PLF 14-EVD P1164-E 1/4 HP, 1625 RPM, 115/230V, 3.6/1.8A PLF 14-EVDL P1168-E3 1/4 HP, 1625 RPM, 115/230V...
  • Page 7 16" Direct Drive Component Qty. Description G1028 Turn Clip G1050 PLF Mount Arm Link Bracket G1051-16 PLF Motor Arm G1910-16 16" Fan Guard G2809-16B PLF Housing G2900-16 16" Shutter Assembly G2950-16 16" 3/45 Rotair Blade PLF 16-EVD P1164-E3 1/4 HP, Max.1625 RPM, 115/230V PLF 16-EVDL P1168-E 1/4 HP, 1625 RPM, 115/230V...
  • Page 8 18" Direct Drive Component Qty. Description G1028 Turn Clip G1050 PLF Mount Arm Link Bracket G1051-18 PLF Motor Arm G1910-18 18" Fan Guard G2809-18B PLF Housing G2900-18 18" Shutter Assembly G2950-18 18" 3/4 Rotair Blade PLF 18-FVD P1164-F3 1/3 HP, Max.1625 RPM, 115/230V, 3.6/1.8A PLF 18-FVDL P1168-F 1/3 HP, 1625 RPM, 115/230V...
  • Page 9 20" Direct Drive Component Qty. Description G1028 Turn Clip G1050 PLF Mount Arm Link Bracket G1051-20 PLF Motor Arm G1910-20 20" Fan Guard G2809-20B PLF Housing G2900-20 20" Shutter Assembly G2950-20 20" 3/45 Rotair Blade PLF 20-FVD P1164-F3 1/3 HP, Max.1625 RPM, 115/230V, 3.6/1.8A PLF 20-FVDL P1168-F 1/3 HP, 1625 RPM, 115/230V...
  • Page 10 24" Direct Drive Component Qty. Description G1028 Turn Clip G1050 PLF Mount Arm Link Bracket G2983 24" Shutter Assembly G1051-24 PLF Motor Arm G1910-24 24" Spiral Guard G2809-24B PLF Housing PLF 24-M P1166-F3 1/3 HP, 1100 RPM, 115/230V G2950-24M Rotair Blade 24"/6/45 PLF 24-GVD P1168-G 1/2 HP, 1625 RPM, 115/230V...
  • Page 11 36" Direct Drive Component Qty. Description G1028 Turn Clip G1050 PLF Mount Arm Link Bracket G1051-36 PLF Motor Arm G1658-36GV 36" Galv. Shutter Assembly G1900-36 PLF36 Spiral Guard G2809-36B PLF Housing P1170-36DP 1/2 HP, 825 RPM, 4 Lug Mount PLF 36-M P3006-36D 36"...
  • Page 12 36" Belt Drive Component Description Qty. P1174-48BGE 1 HP, 1725 RPM, 115V, Reversable G1028 Turn Clip G1883 Motor Mount Bracket 1 x 14.125 B.D. Shaft - 6 Lug Mount G1885 G1939 Rotary Tensioner Mount Bracket G1658-36V 36 GV. Shutter Assembly G1896-GV-3 Bearing Mount Case G1900-36...