Environmental Specifications - HP XP P9500 Owner's Manual

Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

NOTE:
NOTE:
(even though there are no technical issues). Only upgrade orders can ship with difference phase
PDUs in a system.
Figure 23 P9500 AC power configuration diagram

Environmental specifications

The following table lists the environmental specifications of the P9500 storage system.
Table 31 P9500 environmental specifications
Item
Temperature
(ºF / ºC)
Relative Humidity
(%)
Max. Wet Bulb
(ºF / ºC)
Temperature
Deviation
per hour)
(ºF / ºC)
Vibration
to 10Hz: 0.25 mm
Downloaded from
www.Manualslib.com
PDU models can be changed in the field using offline maintenance procedures.
When ordering systems, HP does not allow mixtures of different phase PDUs in a system
Operating
60.8 - 80.9 /
16 to 32
20 to 80
2
78.8 / 26
10 to 300 Hz
0.49 m/s
manuals search engine
Not Operating
- 1 8 - 109.4 / - 1 0 to 43
- 1 8 to 95 / - 1 0 to 35
8 to 90
80.6 / 27
50 / 10
50 / 10
5 to 10 Hz: 2.5 mm
1
10 to 70 Hz: 4.9 m/s
In Storage
-45 - 140
8
-25 to 60
5 to 95
84.2 / 29
68 / 20
Sine Vibration:
1
1
4.9 m/s
, 5 min.