17. Electrical System
Disconnect the positive cable of the starter motor.
Disconnect the coupler of the relay.
Connect an ohmmeter to the large terminal end.
Connect the yellow/red cable to the battery
positive terminal and the green/yellow cable to the
battery negative terminal.
Check the continuity of the large terminal end.
If there is no continuity, replace the relay.
Removal of Starter motor
2 bolts
Turns off the main switch
Remove the luggage box.
Disconnect the coupler of the start relay.
Disconnect the cable negative terminal of the
battery.
Disconnect the starter motor power cable.
Loosen 2 bolts & remove starter motor.
Installation of starter motor
Install in reverse order of removal procedures.