Fixtures must be installed by a Qualified electrician in accordance with all
national and local electrical and construction codes and regulation.
.
4.1 Placing the fixture head covers
The plastic head covers cannot be interchanged otherwise the fixture head will by overheated and the light
source will be switched off. The rectangular array of air vents has to be over two axial fans.
Pay attention to correct placing the covers on the head according to the following drawing:
4.2 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The Robin 300 Plasma Plasma Spot is equipped with auto-switching power supply that automatically adjusts
to any 50/60Hz AC power source from 100-240 Volts.
Install a suitable plug on the power cord, note that the cores in the power cord are coloured according to the
following table. The earth has to be connected!
If you have any doubts about proper installation, consult a qualified electrician.
Core (EU)
Brown
Light blue
Yellow/Green
4.3 Replacing the colour filters and gobos
Install the colour filters or gobos with the device switched off only.
Colour filters
1. Disconnect the fixture from mains and allow it to cool.
2. Remove the top plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover.
3. Turn the colour wheel to the desired position.The dichroic filters are fixed on the colour wheel by the
magnets.
4. Installation
Core (US)
Connection
Black
Live
White
Neutral
Green
Earth
DANGER!
Unplug from mains before!
6
Plug Terminal Marking
L
N