Advertisement

Quick Links

Version1.6


Advertisement

Table of Contents
loading

Summary of Contents for V Robin 300 plasma spot

  • Page 1 Version1.6...
  • Page 2: Table Of Contents

    Robin 300 Spot Table of contents 1. Safety instructions ......................3 2. Operating determination ....................4 3. Fixture exterior view ...................... 5 4. Installation........................6 4.1 Placing the fixture head covers .................. 6 4.2 Connection to the mains..................... 6 4.3 Replacing the colour filters and gobos ............... 6 4.4 Rigging the fixture.......................
  • Page 3: Safety Instructions

    CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this device have to: - be qualified - follow the instructions of this manual CAUTION!
  • Page 4: Operating Determination

    2. Operating determination This device is a moving head for creating decorative effects and was designed for indoor use only. If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
  • Page 5: Fixture Exterior View

    3. Fixture exterior view 1 - Front lens 2 - Tilt lock 3 - Pan lock 4 - Base 5 - Moving head 6 - Arm The head should be locked for transportation- the tilt lock latch (2) and the pan lock latch (3) have to be in the locked positions.
  • Page 6: Installation

    4. Installation Fixtures must be installed by a Qualified electrician in accordance with all national and local electrical and construction codes and regulation. 4.1 Placing the fixture head covers The plastic head covers cannot be interchanged otherwise the fixture head will by overheated and the light source will be switched off.
  • Page 7 4. Release the dichroic filter from the colour wheel by inclining it from its position to break the power of the magnet. Protect the glass filter with a piece of paper or clout. 5. Insert a new dichroic filter into the colour wheel. 6.
  • Page 8: Rigging The Fixture

    4.4 Rigging the fixture The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation. The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails.
  • Page 9 Truss installation 1.Bolt each clamp (1) to the omega holder (3) with M12 bolt and lock nut through the hole in the holder. 2.Fasten the omega holders on the bottom of the base by inserting both quick-lock fasteners (4) into the holes of the base and tighten fully clockwise.
  • Page 10: Dmx-512 Connection

    4.5 DMX-512 connection The fixture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.The sockets are wired in parallel. Only use a shielded twisted-pair cable designed for RS-485 and 3-pin or 5-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with another.
  • Page 11: Ethernet Connection

    4.6 Ethernet connection The fixtures on a data link are connected to the Ethernet with ArtNet communication protocol.The control soft- ware running on your PC (or light console) has to support Art-Net protocol. Art-Net communication protocol is a 10 Base T Ethernet protocol based on the TCP/IP.Its purpose is to allow transfer of large amounts of DMX 512 data over a wide area using standard network technology.
  • Page 12 Ethernet / DMX operation Options “Ethernet/DMX” has to be selected from the “Ethernet Mode” menu on the first fixture (connected to the Ethernet) in the fixture chain,next fixtures have standard DMX setting. Connect the Ethernet-input of the first fixture in the data chain with the network. Connect the DMX output of this fixture with the input of the next fixture until all fixtures are connected to the DMX chain.
  • Page 13: Remotely Controllable Functions

    5. Remotely controllable functions Lamp The LIFI™ ENT 31-02 is a category of solid-state lighting. LIFI™ like a electrodeless lighting technology does not require electrodes to power the bulb and therefore has a completely sealed, contaminant free and long lasting bulb.
  • Page 14: Control Menu Map

    6. Control menu map Default settings=Bold print Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Addressing Settings DMX Address 00-55 Ethernet Settings Ethernet Mode Disable ..ArtNet/MaNet Ethernet To DMX IP Address/Net Mask Default IP Address Custom IP Address Net Mask ArtNet Universe...
  • Page 15 Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Fixture Temperatures Head Temperatures Ambient Temperatures Base Temperatures Personality User Mode User A Settings User B Settings ..User C Settings DMX Presets Mode 1 Mode 2 Mode 3 View Selected Preset Pan/Tilt Settings Pan Reverse...
  • Page 16 Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Zoom 0-55 Focus 0-55 MusicTrigger Off, On None Preset Playback Test Prg. 1 Prg. 2 Prg. 3 Play Program Play Program 1 Play Program 2 Play Program 3 Edit Program Edit Program 1 Start Step...
  • Page 17: Control Menu

    7. Control menu The Robin 300 Plasma Spot is equipped with the QVGA Robe touch screen with battery backup which allows to set the fixture´s behaviour according to your needs, obtain information on its operation, test its vari- ous parts and lastly program it, if it has to be used in a stand-alone mode.
  • Page 18: Tab " Address

    Touch any part of the screen or press the [ENTER/Display On] button to display the initial screen with the cur- rent stored DMX address: Touch the green arrow at the bottom right corner of the screen or press the [ENTER/Display On] button to enter the "...
  • Page 19: Tab "Information

    Resetable Hours.- The item shows the number of the operation hours with the lamp on that the Robin 300 Plasma Spot has been powered on since the counter was last reset. In order to reset this counter to 0, touch the text box next to the item "Resetable Hours:"...
  • Page 20: Tab "Personality

    7.3 Tab "Personality" User mode - The Robin 300 Plasma Spot allows you to recall up to 3 user settings. After switching the fixture on for the first time, the User A settings is active. Now all changes made in the “Personality” menu , ”Address- ing”...
  • Page 21 DMX Preset - Use the menu to select desired channel mode..Mode 1 - 31 control channels ...Mode 2 - 24 control channels ...Mode 3 - 22 control channels ...View Selected Preset - Use the menu to display channels included in the selected mode. Pan/Tilt Settings - Use the menu set behaviour of both pan and tilt movements.
  • Page 22: Tab "Manual Control

    Play Program 2 - The option starts user program No. 2. Play Program 3 - The option starts user program No. 3. Edit Program - Use the menu to create or to edit desired program. The Robin 300 Plasma Spot offers 3 free programs, each up to 100 steps.
  • Page 23 4 From the list of effects touch desired effect and set its value. Browse throw the list by touching the [up arrow] and [down arrow] and set all desired effects. An item "Step Time" (value of 0-25.5 sec.) is the time during which effects last in the current step 5.
  • Page 24 2. Make a new directory ( e.g. Robe_Uploader) on your hard disk and download the software to it. 3. Unpack the program from the archive. If the Robe fixture is produced in both magnetic ..and electronic ballast version, name of DMX Software Uploader is the same for both versions.
  • Page 25: Icon "Lamp Menu

    RDM allows explicit commands to be sent to a device and responses to be received from it. The list of commands for Robin 300 Plasma Spot is the following. Parameter ID Discovery command SET command...
  • Page 26: Error And Information Messages

    LAMP_ON_MODE . DEVICE_HOURS LAMP_HOURS LAMP_STRIKES ...Another options for this command (only for Robe´s fixtures): value PARAMETER_DATA=0x84 - lamp OFF by DMX value on DMX channel value PARAMETER_DATA=0x88 - lamp OFF if DMX is not present ...Commands relative resetable values 9. Error and information messages...
  • Page 27: Technical Specifications

    position. Clean Air Filters The message informs that the item "Elapsed Time" in the "Fixture Information" menu is at 0 value. Clean air filters and reset this counter. Messages concerning the lamp and lamp driver: Lamp Starting The message informs you that the lamp status is on but the lamp does not light. Overtemp The message informs you that the fixture had been overheated and the lamp was shut down due to excessive temperature.
  • Page 28 Static gobo wheel: 9 replaceable ‘SLOT&LOCK’ metal gobos , outside diameter=26.9mm, image diameter=22.5mm, aluminium, thickness=0.5 mm Gobo wheel continuous rotation Rotating gobo wheel: 7 glass gobos can be indexed and rotated in both directions at different speeds Gobo wheel continuous rotation Glass gobos: outside diameter=26.8 mm, max.
  • Page 29: Maintenance And Cleaning

    Maximum ambient temperature : 40° C Maximum housing temperature : 80° C Minimum distances Min. distance from flammable surfaces: 1 m Min. distance to lighted object: 2 m Total heat dissipation 1330 BTU/h (calculated) Weight (net): .kg. Dimensions (mm) Accessories - Omega holder (No.99010420)........2 pcs - Gobo-set 16.(No.15050025)........1 pcs Optional Accessories...
  • Page 30 DMX protocol Robin 300 Plasma Spot  ‐ DMX protocol, version 1.3 Mode/channel DMX  Type of  Function Value control 0 ‐ 255 Pan movement by 540° proportional Pan Fine 0 ‐ 255 Fine control of pan movement proportional Tilt 0 ‐ 255 Tilt movement by 280° proportional Tilt fine 0 ‐ 255 Fine control of tilt movement proportional Pan/Tilt speed , Pan/Tilt time Max. speed (tracking mode) step P./T. speed‐set Speed Mode in menu: Pan/Tilt Mode 1 ‐ 255 Speed from max. to min. (vector mode) proportional P./T. time ‐ set Time Mode in menu: Pan/Tilt Mode 1 ‐ 255 Time from 0.1 s to 25.5 sec.  proportional Power/Special functions Reserved   0‐29 step To activate following functions, stop in DMX value for at least 3 s  and shutter must be closed at least 3 sec. („Shutter/Strobe”  channel 29/23/21 must be at range: 0‐31 DMX). Corresponding ...
  • Page 31 DMX protocol Mode/channel DMX  Type of  Function Value control Green proportional Light red proportional Amber proportional UV filter proportional 128‐129 White step Positioning 130‐137 Deep red step 138‐145 Deep blue step 146‐153 Orange step 154‐163 Green step 164‐171 Light red step 172‐181 Amber step 182‐189 UV filter step 190 ‐ 215 Forwards rainbow effect from fast to slow proportional 216 ‐ 217 No rotation...
  • Page 32 DMX protocol Mode/channel DMX  Type of  Function Value control 160‐167 Macro 20 step 168‐175 Macro 21 step 176‐183 Macro 22 step 184‐191 Macro 23 step 192‐199 Macro 24 step 200 ‐ 207 Macro 25 step 208 ‐ 215 Macro 26 step 216 ‐ 223 Macro 27 step 224 ‐ 231 Macro 28 step 232 ‐ 239 Macro 29 step 240 ‐ 243 Macro 30 proportional 244 ‐ 249 Random macro selection by audio control step (Set microphone sensitivity in menu "PErsonality")
  • Page 33 DMX protocol Mode/channel DMX  Type of  Function Value control 170 ‐ 179 Gobo 7 proportional 180 ‐ 189 Gobo 8 proportional 190 ‐ 199 Gobo 9 proportional 200 ‐ 201 Open/hole step 202 ‐ 221 Forwards gobo wheel  rotation from fast to slow proportional 222 ‐ 223 No rotation 224 ‐ 243 Backwards gobo wheel  rotation from slow to fast proportional 244 ‐ 249 Random gobo  selection by audio control step (Set microphone sensitivity in menu „Personality”) 250 ‐ 255 Auto random gobo  selection from fast to slow proportional Static gobo wheel‐fine 0 ‐ 255 Fine positioning proportional Rotating gobo wheel In the range of 0‐59 DMX  the gobo selection speed is controlled  by the Effect Speed channel.
  • Page 34 DMX protocol Mode/channel DMX  Type of  Function Value control 200 ‐ 201 Open/hole   step 202 ‐ 221 Forwards gobo wheel  rotation from fast to slow proportional 222 ‐ 223 No rotation step 224 ‐ 243 Backwards gobo wheel  rotation from slow to fast proportional 244 ‐ 249 Random gobo  selection by audio control step (Set microphone sensitivity in menu „Personality”) 250 ‐ 255 Auto random gobo  selection from fast to slow proportional Rot. gobo  indexing and rotation Gobo indexing  ‐ set position on channel 17/15/13 0 ‐ 255 Gobo indexing proportional Gobo rotation  ‐ set position on channel  17/15/13 No rotation step 1 ‐ 127 Forwards gobo rotation from fast to slow proportional 128 ‐ 129 No rotation step 130 ‐ 255 Backwards gobo rotation from slow to fast proportional Rot. gobo indexing/rotation ‐ fine...
  • Page 35 DMX protocol Mode/channel DMX  Type of  Function Value control Open step 1 ‐ 179 From max.diameter to min.diameter proportional 180 ‐ 191 Closed step Pulse effects with Iris blackout: 192 ‐219 Pulse opening from slow to fast proportional 220 ‐ 247 Pulse closing from fast to slow proportional 248 ‐ 249 Random pulse opening (fast) step 250 ‐ 251 Random pulse opening (slow) step 252 ‐ 253 Random pulse closing (fast) step 254 ‐ 255 Random pulse closing (slow) step Iris ‐ fine 0 ‐ 255 Fine iris movement proportional Zoom 0 ‐ 255 Zoom from max. to min.beam angle proportional Zoom ‐ fine...

This manual is also suitable for:

300 plasma spot

Table of Contents