4-3-12. Y Output Level Adjustment
Equipment
: Oscilloscope
To be extended
: YD-26 board
Preparation
¢ §3 (Y 2nd AGCVYD-26 board
> "ON"
Test point
: TP11 (GND: E6)/YD-26 board
Adjusting point : @RV9 (Y LEVEL)/YD-26 board
Specification
:A=700+7 mV p-p
'SAMPL GATE
TP4 TP7
Nees 66
'oh
Q
ss[]
%
t
AY2 Avs OTPS
o
6
Oo
LY
BLACK S/H SYNC SH
S4
CZnd ace
€7
oO
§ 3 — evcannsa
TP14 77>, RVIt
oO
Q
RV13
RV14
OFFSET ADS
PULSET
CABLE LENGTH
St
Oo
38
4-18
4-4.
CHROMA Cable Compensation
System Adjustment
4-4-1.
45 MHz Carrier Level Adjustment
Equipment
: Oscilloscope
To be extended
: YD-26 board
Test poini
: TP16 (GND: E8)/YD-26 board
Adjusting point : @RV15 (C CARR LEVEL)/
YD-26 board
Specification
:A=400+20mVp-p
(BW LIMIT/Oscilloscope > "OFF" )
TP
YLEVEL@®
AVS
@&e
TPI2—-RVI7
O
URvcever
iS)
TP19
RVI8
ou
AVIS
CCARLEV
YD-26 Board (A SIDE)
CCU-TX7 (E)/V1