The injection telltale light is controlled upon every switching to "ON" by the 3-second timing generated
by the digital instrument. This step is normally interrupted by the injection control unit control. The timing
lasts 5 seconds.
The diagnostic tester is not programmed to check this circuit.
Proceed as follows:
Specific tooling
020680Y Diagnosis Tool
1 - Turn the switch to the "ON" position Turn the emergency switch to position "RUN". Keep the side
stand raised. Make sure the light goes on for 5 seconds.
CIRCUIT LAYOUT
Specification
Instrument panel
Fuse
Electronic control unit
Specification
TERMINAL: 15 - 23
TERMINAL: 15 - 23
Desc./Quantity
[
]
P
Desc./Quantity
CONDITIONS: DURING THE CHECK
- Switch set to "ON"
- Side stand raised
- Switch to "RUN"
STANDARD VALUES : O V
CONDITIONS: AFTER THE CHECK
- Switch set to "ON"
- Side stand raised
- Switch to "RUN"
STANDARD VALUES : Battery voltage
Injection
7.5 A