Removing The Bake Burner Safety Valve Mounting Bracket; Removing The Bake Burner OriCe Assembly And Mounting Bracket; Removing The Bake Burner OriCe - Electrolux E30GF74GPS Technical & Service Manual

30 and 36 inch all gas range
Hide thumbs Also See for E30GF74GPS:
Table of Contents

Advertisement

3.
Remove the screw holding the valve to the
valve mounting bracket and slide the valve out.
Removing the bake burner safety
valve mounting bracket:
1.
Disconnect power, turn the gas off to the oven
and remove the kickplate.
2.
Remove the bake burner safety valve from its
bracket.
3.
Remove the (2) screws holding the bracket to
the front panel and lift the bracket off.
Removing the bake burner orifice
assembly and mounting bracket:
1.
Disconnect power, turn the gas off to the oven
and remove the kickplate.
2.
Using a 5/8" wrench disconnect the flexible gas
line from the orifice assembly.
3.
Remove the (2) screws holding the orifice
assembly mounting bracket to the front panel
and pull the orifice assembly out.
Note: When reinstalling the orifice assembly
adjust the orifice assembly so that the
bake burner is level.
Removing the bake burner orifice:
1.
Disconnect power, and remove the kickplate.
2.
Remove the orifice assembly and mounting
bracket.
83