12.

Quick Connect Multi System Installation

• The Quick Connect Multi System allows the installation of two units together utilizing only the Quick
Connect Cord.
The Quick Connect Cord is 2m. long. Install the units no more than 950mm apart from each other
to ensure the cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the difference in pipe length
between the two units).

System Diagram

Quick Connect
Cord
Cord
Connector
Typical Plumbing
Make this distance as short
as possible.
* The hot water temperature
will become unstable as the
pipe length increases.
• Insulate the hot water piping to prevent heat loss. Insulate and apply heating materials to the cold
water supply piping to prevent heat loss and freezing of pipes when exposed to excessively cold
temperatures.
24
Installation Instructions
Cord
Connector
Terminal Block
Remote Controller
Remote Controller Cord
G
Distance at center: max.950mm.
Union
Union
Quick Connect
Union
Cord
Shutoff
Gas Valve
Valve
Shutoff Valve
Leave enough clearance around the plumbing to
apply insulation. It will be necessary to add
bends to the piping to ensure that this clearance
is available.
* When two apparatuses are connected,
only one apparatus can connect remote
controller.
Note: Connect the remote
controller to only one
of the units.
Gas Supply Piping
Cold Water Supply
Hot Water
Shutoff
Size the piping to allow for the maximum
flow rates of the units.
Valve
Hot Water
Cold Water