Before Installation - Bosch BC3200RABC3200RA5 Installation Manual

Internal/external model condensing gas water heater
Table of Contents

Advertisement

3.

Before Installation

Checkup
• Check the fixing brackets and exhaust vent yearly to make sure they do not need to be replaced.
Do not install unit in a bathroom or other occupied room, installation in an improper location may
cause failures or fire. In accordance with AS5601.
Check the Gas
• Check that the data plate (located inside of front cover) or
a temporary label (located on the front cover)
indicates the correct type of gas.
• Check that the gas supply line is sized for
217 MJ/hr for this unit.
• DO NOT OPERATE WITH ANY OTHER GAS TYPE.
Check the Power
• The power supply required is 230/240VAC, at 50Hz.
Using the incorrect voltage may result in fire or
electric shock.
Warning labels
• Located on the right side of the casing -PLEASE READ THESE LABELS CAREFULLY!
Use Extreme Caution if Using With a Solar Pre-Heater
• Using this unit with a solar pre-heater can lead to unpredictable output temperatures and
possibly scalding. If absolutely necessary, use mixing valves to ensure output temperatures do
not get to scalding levels.
Do Not Use Equipment for Purposes Other Than Those Specified
• Do not use for other than increasing the temperature of the water supply, as unexpected accidents
may occur as a result.
Check Water Supply Quality
• If the water supply is hard, acidic or otherwise impure, treat the water with approved methods in
order to ensure full warranty coverage.
4
Installation Instructions
DANGER
WARNING
CAUTION
BC3200RA
MODEL
GAS TYPE
: NG
GAS CONSUMPTION
: XXX MJ/hr
HEAT OUTPUT
: XX.X kW
ELECTRICAL RATING
: AC230/240V 50Hz
RATED POWER
: XX.XW
HOT WATER SUPPLY CAPACITY
: XXL/min RAISED 25 C
GAS PRESSURE TEST POINT
: MAX : 0.73kPa
: M I N : 0.18kPa
GAS SUPPLY PRESSURE
MAX 3 0kP