Setting And Verifying The Combustion Setting - Westinghouse WBRCNG140W Installation Manual

Gas fired residential combi boiler
Table of Contents

Advertisement

Minimum Pressure
Maximum Pressure
Table 23 – Gas Pressure Requirements
6. Remove the manometer. Close the screw on the gas inlet pressure tap.
J. SETTING AND VERIFYING THE COMBUSTION SETTING
1. After the appliance has fired, flip DIP switch seven (7) to the ON position (low fire). Proceed to check appliance combustion values.
NOTE: Use a combustion analyzer to ensure CO and CO
It is required to use a combustion analyzer to verify final adjustment according to the combustion chart (Table 24). Failure to do so
could result in serious personal injury or death.
If the readings obtained are lower or higher than the combustion readings in Table 24, use a 4mm Allen key to adjust the offset screw in
a clockwise (positive) or counterclockwise (negative) direction (approximately 1/4 turn). See Figure 44. Check your combustion values.
Repeat this procedure until the values obtained on the combustion analyzer agree with those stated in Table 24.
NOTE: If the appliance makes a whistling sound (harmonics) at low fire, adjust the offset screw in a clockwise (positive) direction
(approximately 1/8 turn). Check your combustion values and ensure they agree with those stated in Table 24 before proceeding.
It is very important that combustion settings be set within the recommended CO measurements listed in Table 24. Visually looking at
the burner does not determine combustion quality. Failure to measure combustion with a Combustion Analyzer and set the throttle
within the recommended CO measurements could result in property damage, severe personal injury, or death.
FAN SPEED
CO PPM
CO
(%)
2
Table 24 – Combustion Settings
2. When low fire settings have been obtained, flip DIP switch seven (7) to its original (OFF) position. This will return the appliance to
normal mode.
3. Flip DIP switch six (6) to ON (high fire). Again check combustion readings with a combustion analyzer.
4. When complete, flip DIP switch six (6) to its original (OFF) position. This will return the appliance to normal mode.
5. Allow appliance to operate normally. Ensure it is operating properly.
6. Reinstall the appliance front cover.
7. Use a Phillips Head screwdriver to reinstall the appliance top cover.
LP GAS
3.5" WC
14" WC
COMBUSTION SETTINGS
NATURAL GAS
LOW
HIGH
<175
<175
8 - 10
8 ½ - 10 ½
Minimum Pressure
Maximum Pressure
values are within the range shown in Table 24.
2
LP GAS
LOW
<175
9 – 10 ½
9 ½ - 11
NATURAL GAS
HIGH
<175
Figure 44 – Gas Valve Offset Screw
WHL-012 REV. 12.17.14
57
3.5" WC
14" WC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wbrclp140wWbrcng140fWbrclp140f

Table of Contents