Part 7 - Gas Piping; Gas Pipe Sizing Tables; Gas Pipe Sizing; Natural Gas Pipe Sizing - Westinghouse WBRCNG140W Installation Manual

Gas fired residential combi boiler
Table of Contents

Advertisement

If using a condensate pump, select one approved for use with condensing boilers and furnaces. The pump should have an overflow
switch to prevent property damage from condensate spillage.
It is very important that the condensate piping be no smaller than ¾". To prevent sagging and maintain pitch, condensate piping should
be supported with pipe supports, and pitched ¼" per foot to allow for proper drainage.
The condensate line must remain unobstructed, allowing free flow of condensate. If condensate freezes in the line, or if line is
obstructed in any other manner, condensate can exit from the tee, resulting in potential water damage to property.
PART 7 – GAS PIPING
To avoid serious injury or death, the gas line installation and the gas line inlet pressure test must be done by a licensed professional.
Always match the appliance with the type of gas supplied to the unit (natural gas or LP gas). Propane ready appliances have the suffix
"LP" after the model serial number.
Make sure the gas line pressures are within normal limits. Pressures outside normal limits can result in poor performance and
hazardous operating conditions.
Failure to ensure the appliance is set to operate on the provided gas supply could result in property damage, personal injury, or death.
A. GAS PIPE SIZING TABLES

1. Gas Pipe Sizing

This information is for reference use only. Refer to gas pipe manufacturer specifications for actual delivery capacity. The DOE standard
for Natural Gas is 1100 BTU/ft

2. Natural Gas Pipe Sizing

The following tables list maximum capacity of pipe in cubic feet of gas per hour for gas pressures of 0.5 psi or less and a pressure drop
of 0.5 inches water column, based on a 0.60 specific gravity for natural gas.
Maximum Natural Gas Delivery Capacity – Length of Corrugated Stainless Steel Pipe in Feet
Pipe Size
10
½"
82
¾"
192
1"
383
1 ¼"
639
1 ½"
1260
2"
2930
Table 11 – Natural Gas Delivery Capacity – Corrugated Stainless Steel Pipe – Refer to ANSI Z223.1 – National Fuel Gas Code,
Latest Edition
Maximum Natural Gas Delivery Capacity – Length of Black Iron Pipe (Sch. 40 Metallic) in Feet
Pipe Size
10
½"
172
¾"
360
1"
678
1 ¼"
1390
1 ½"
2090
2"
4020
Table 12 – Natural Gas Delivery Capacity – Black Iron Pipe – Refer to ANSI Z223.1 – National Fuel Gas Code, Latest Edition
FIRE AND/OR EXPLOSION HAZARD
3
. Contact the local gas supplier for actual BTU/ft
Cubic Feet per Hour (0.60 Specific Gravity, 0.5 WC Pressure Drop)
20
30
58
47
137
112
269
218
456
374
888
723
2080
1700
Cubic Feet per Hour (0.60 Specific Gravity, 0.5 WC Pressure Drop)
20
30
118
95
247
199
466
374
957
768
1430
1150
2760
2220
3
rating.
40
50
41
37
97
87
188
168
153
325
292
267
625
559
509
1470
1320
1200
40
50
60
81
72
65
170
151
137
320
284
257
657
583
528
985
873
791
1900
1680
1520
60
80
100
37
29
26
80
69
62
132
118
232
208
440
393
1040
933
80
100
56
50
117
104
220
195
452
400
677
600
1300
1160
WHL-012 REV. 12.17.14
27
150
200
20
18
48
44
91
82
171
148
320
277
762
661
150
200
40
34
83
71
157
134
322
275
482
412
928
794