Installer Mode - Westinghouse WBRCNG140W Installation Manual

Gas fired residential combi boiler
Table of Contents

Advertisement

Press the
button again to return to Operation Mode.
NOTE: The Control System will not allow the changes if Lock Mode is activated. Lock Mode will have to be turned off before making
further changes.
Parameter
O: ot
A: Li or A: GA
b: It
C: Fr
d: Lc
E: oP
F: dH
H: Eh
I: St
Parameter
J: oH
1: PH
2: rh
Burner Operation
L: rt
3: rH
Time
4: It
5: IH
Displays output condition for internal primary pump and
three way valve.
P: Ou
Table 19 – Status Mode Display Screen Descriptions
I. INSTALLER MODE
Installer Mode will activate when the
powered on, press the
Figure 36 – Installer Mode Screens
Toggle through items that can be viewed/changed by turning the dial
displayed items can be changed by turning the dial
button again to save settings.
To leave Installer Mode, press the
Display
Default
1: EH
E0:00
2: cE
OFF
3: In
OFF
4: Fu
GA
Detail
Outdoor temperature
DHW Water flow rate
CH return water temperature
FAN speed (RPM)
Lock function (Lock)
CH supply temperature (Operating temperature)
DHW outlet temperature
Exhaust temperature
N/A
Detail
CH water overheat temperature
Supply power time
Burner operation time
Burner operation time
Ignition cycles
Ignition cycles
button is pressed and held for five seconds while the display is powered OFF. If the display is
button to turn it off before pressing and holding the
button again. The display will return to power off mode.
Detail
Error history up to 10
Delete Error history
Initialized system
Change unit for water
volume
- Off
- On
. To view/change an item, press the
counterclockwise to lower and clockwise to raise the displayed value. Press the
Check last 10 error codes (E0 - E9)
Select "ON" to delete error code history
Select "ON" to reset to factory setting
(Burner operation time, Ignition cycles, and Supply power time will not be
Description
Current outdoor sensor temperature
Current flow (Li: LPM, GA: GPM)
Current CH return water temperature
Current fan speed (RPM)
Lock Mode "ON"/"OFF"
Current CH supply temperature
Current DHW outlet temperature
Current exhaust temperature
Not Used (Default is 0)
Description
Current temperature on the overheating sensor.
L:rt display on
sub menu
st
1
Icon
Not Used
Primary Pump
button for five seconds.
Description
Range: ON or OFF
reset)
Range: ON or OFF
Range: GA or Li
45
Unit : 100 hour
Unit : 1 hour
Unit : 1,000 hour
Cycle : 10 times
Cycle : 10,000 times
nd
rd
2
Icon
3
Icon
Internal
3 Way
Valve
button. Some
WHL-012 REV. 12.17.14