iCharger 3010B User Manual page 10

Synchronous balance charger/discharger
Table of Contents

Advertisement

iCharger Synchronous Balance Charger/Discharger
NiCd Sensitivity
DeltaV
Default
-
Dec
Dec
Inc
NiMH/NiCd Check
Delay
0min
-
Dec
Dec
Inc
Temp. Cut-Off
ON
50℃
-
-
+
Dec
Dec
Inc
Dec
Inc
Safety timer
ON
120min
-
+
-
Dec
Dec
Inc
Dec
Inc
Capacity Cut-Off
ON
5000mAh
-
+
-
Dec
Inc
Dec
Dec
Inc
Input limit 50.0
Cut-Off
4.50V
-
Dec
Dec
Inc
Watt Limit (W)
CHG:AUTO DCHG:60
-
-
+
Dec
Dec
Inc
Dec
Inc
Usually, the NiCd battery voltage will drop a little right after reaching full
charge. This is known as -△V. You can alter the iCharger's delta-peak
detection sensitivity.
Range: 1 – 20mV/Cell. (8mV/Cell, default)
+
Inc
When NiMH&NiCd batteries are deeply discharged or left unused for a long
time, they will produce a false -△V which stops charging early. You can
disable -△V testing to avoid this problem.
Range: 0 – 30min (0, default)
+
Inc
Battery upper temperature limit. The battery temperature can be monitored
with the attached temperature sensor. In order to protect the battery from
damage due to high temperatures the iCharger will stop charging or
discharging immediately if the temperature exceeds the cut-off setting.
+
Users can choose ℃ or
Inc
Range: 20 – 80℃(68 – 176
Charging time upper limit. The charging process will stop immediately if it
exceeds the set value.
Range: 1 – 999min
+
Inc
Capacity protection. The charging/discharging process will stop immediately
if the calculated charge input/drained exceeds the set value.
Range: 100 – 99900mAh
+
Inc
Input
current
charging/discharging process will stop immediately if the input voltage falls
below the set value.
Voltage Range: 4.50 – 32.00V (4.50V, default)
Current Range: 1.0A – 50.0A(50.0A, default)
+
Note: Current limit is not very accurate, which may be 20% difference, max.
Inc
Charge/Discharge power limit. The maximum charge/discharge power of
iCharger can be adjusted in order to limit internal temperature and to
protect the input current from
the iCharger can adjust the output charging power according to the input
capability.
+
CHG: 50 –1000W and AUTO. DCHG: 5 –80W(60 W, default)
Inc
Note: The maximum charge power capacity is also limited by input current.
The maximum input current of 3010B is about 50A, and Wmax ≈ Imax *
Vin * 90%. (For example, when the input voltage is 15V, the maximum
charge power capacity ≈50×15×90%=675W).
1000
900
800
700
600
500
400
300
200
100
5
o
F as the temperature unit
o
o
F).
F = (9/5)×℃+32.
limit
&
Input
voltage
over-loading. When the limit is set to AUTO
iCharger3010B: MAX. OUTPUT POWER vs. INPUT VOLTAGE
7
9
11 13 15 17 19 21 23 25 27 29 31 33 35 37
Input voltage(V)
-10-
3010B
protection
lower
limit.
The

Hide quick links: