1.3 CHARGED SECTION AND HIGH VOLTAGE GENERATING POINT
7 Charged Section
The places where the commercial AC power is used
without passing through the power supply transformer.
If the places are touched, there is a risk of electric shock.
In addition, the measuring equipment can be damaged if it
is connected to the GND of the charged section and the
GND of the non-charged section while connecting the set
directly to the commercial AC power supply. Therefore,
be sure to connect the set via an insulated transformer and
supply the current.
7 Charged Section
(Power supply primary side)
1. AC Power Cord
2. AC Inlet with Filter
3. Power Switch (S1)
4. Fuse (In the MAIN POWER ASSY)
5. STB Transformer and Converter Transformer
(In the MAIN POWER ASSY)
6. Other primary side of the MAIN POWER ASSY
For the places, refer to the EXPLODED VIEWS, the
SCHEMATIC DIAGRAM and the PCB CONNECTION
DIAGRAM sections.
X DRIVE (B) ASSY
POWER SWITCH (S1)
4
X DRIVE (A) ASSY
AC INLET
Y DRIVE (B) ASSY
7 High Voltage Generating Point
The places where voltage is 100V or more except for the
charged places described above. If the places are touched,
there is a risk of electric shock.
1. POWER SUPPLY MODULE (170V)
2. X DRIVE (A) ASSY
3. X DRIVE (B) ASSY
4. Y DRIVE (A) ASSY
5. Y DRIVE (B) ASSY
6. SCAN ASSY (A),(B),(C),(D) (150V)
For the places, refer to the EXPLODED VIEWS, the
SCHEMATIC DIAGRAM and the PCB CONNECTION
DIAGRAM sections.
Part is charged section.
Part is the high voltage generating points other than
the charged section.
POWER SUPPLY MODULE
SCAN C ASSY
SCAN D ASSY
(170V)
(170V)
(170V)
(170V)
Y DRIVE (A) ASSY
SCAN A ASSY
SCAN B ASSY