Garmin GNS 530W Installation Manual page 16

500w series
Hide thumbs Also See for GNS 530W:
Table of Contents

Advertisement

1.4.2
General Specifications
Operating Temperature Range
Humidity
Altitude Range
Input Power Requirements
Input Voltage Range - All Units (Main
Connector)
Input Voltage Range (COM Connector)
GNS 530W
Input Voltage Range (COM Connector)
GNS 530AW
GPS 500W (Main Connector)
GNS 530W, GNS530AW (Main Connector)
GNS 530W (COM Connector)
GNS 530AW (COM Connector)
Superflag Power Requirements
Environmental Testing
The display on the 500W Series unit is a sunlight readable LCD display.
Display Size
Active Area
Resolution
Viewing Angle
(with a 5:1 contrast ratio, min)
Viewing Distance
Page 1-4
Rev. D
-20°C to +55°C. For more details see Environmental
Qualification Form on the Dealers Only page on
www.garmin.com. See Appendix A for part numbers.
95% non-condensing
-1,500 ft to 50,000 ft
10 to 33.2 VDC
11 to 33 VDC
24.1 to 33 VDC
800 mA @ 28 VDC (maximum)
1.6 A @ 14 VDC (maximum)
1.4 A @ 28 VDC (maximum)
3.0 A @ 14 VDC (maximum)
15 mA @ 28 VDC (receive)
3.0 A @ 28 VDC (transmit)
15 mA @ 14 VDC (receive)
6.0 A @ 14 VDC (transmit)
15 mA @ 28 VDC (receive)
3.0 A @ 28 VDC (transmit)
500 mA maximum per superflag output
See Environmental Qualification Form on the Dealers
Only page on www.garmin.com. See Appendix A for
part numbers.
5.0" diagonal
4.02" (W) x 2.95" (H)
320 x 234 pixels
Left/Right:
60°
Up:
35°
Down:
60°
36 inches maximum