Mitsubishi Electric FR-F740-00023 Instruction Manual page 225

F700 series
Hide thumbs Also See for FR-F740-00023:
Table of Contents

Advertisement

Communication operation and setting
Parameter
Parameters Register
41000 to
0 to 999
C2(902)
C3(902)
125(903)
C4(903)
C5(904)
C6(904)
126(905)
C7(905)
C8(930)
C9(930)
C10(931)
C11(931)
C42(934)
C43(934)
C44(935)
C45(935)
216
Parameter Name
Refer to the parameter list (page
41999
55) for the parameter names.
Terminal 2 frequency setting
41902
bias (frequency)
Terminal 2 frequency setting
42092
bias (analog value)
Terminal 2 frequency setting
43902
bias (terminal analog value)
Terminal 2 frequency setting
41903
gain (frequency)
Terminal 2 frequency setting
42093
gain (analog value)
Terminal 2 frequency setting
43903
gain (terminal analog value)
Terminal 4 frequency setting
41904
bias (frequency)
Terminal 4 frequency setting
42094
bias (analog value)
Terminal 4 frequency setting
43904
bias (terminal analog value)
Terminal 4 frequency setting
41905
gain (frequency)
Terminal 4 frequency setting
42095
gain (analog value)
Terminal 4 frequency setting
43905
gain (terminal analog value)
41930
Current output bias signal
42120
Current output bias current
41931
Current output gain signal
42121
Current output gain current
41934
PID display bias coefficient
42124
PID display bias analog value
PID display bias analog value
43934
(terminal analog value)
41935
PID display gain coefficient
42125
PID display gain analog value
PID display gain analog value
43935
(terminal analog value)
Read/Write
The parameter number + 41000 is the
Read/write
register number.
Read/write
The analog value (%) set to C3 (902) is
Read/write
read.
The analog value (%) of the voltage (current)
Read
applied to the terminal 2 is read.
Read/write
The analog value (%) set to C4 (903) is
Read/write
read.
The analog value (%) of the voltage
Read
(current) applied to the terminal 2 is read.
Read/write
The analog value (%) set to C6 (904) is
Read/write
read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
The analog value (%) set to C7 (905) is
Read/write
read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
Read/write
Read/write
Read/write
Read/write
The analog value (%) set to C43 (934) is
Read/write
read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
The analog value (%) set to C45 (935) is
Read/write
read.
The analog value (%) of the current
Read
(voltage) applied to the terminal 4 is read.
Remarks