Mitsubishi Electric FR-F740-00023 Instruction Manual page 213

F700 series
Hide thumbs Also See for FR-F740-00023:
Table of Contents

Advertisement

Communication operation and setting
No.
Item
Fault definition all
7
clear
Parameter clear
8
All parameter clear
9
Parameters
10
Link parameter
11
extended setting
Second parameter
changing
12
(instruction code
HFF=1)
Refer to page 197 for data formats (A, A', B, B', C, D)
REMARKS
Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
For the instruction codes HFF, HEC and HF3, their values are held once written but cleared to zero when an inverter reset or all
clear is performed.
Example) When reading the C3 (Pr. 902) and C6 (Pr. 904) settings from the inverter of station No. 0
Computer Send Data
1)
ENQ 00 FF 0 01 82
2)
ENQ 00 EC 0 01 7E
3)
ENQ 00 5E 0 0F
4)
ENQ 00 60 0 FB
To read/write C3 (Pr. 902) and C6 (Pr. 904) after inverter reset or parameter clear, execute from 1) again.
204
Read
Instruction
/write
Code
Write
HF4
H9696: Faults history batch clear
All parameters return to the initial values.
Whether to clear communication parameters or not can be
selected according to data. ( : clear, : not clear)
Refer to page 322 for parameter clear, all clear, and
communication parameters.
Clear type
Parameter clear
Write
HFC
All parameter clear
When clear is executed for H9696 or H9966, communication-
related parameter settings also return to the initial values.
When resuming operation, set the parameters again.
Executing clear will clear the instruction code HEC, HF3, and
HFF settings.
H00 to
Refer to the instruction code (page 322) and write and/or read
Read
H63
the values as required.
When setting
H80 to
Write
must be set.
HE3
Parameter description is changed according to the H00 to H09
Read
H7F
setting.
For details of the setting, refer to the instruction code (page
Write
HFF
322).
When setting the calibration parameters
H00:Frequency
Read
H6C
H01: Parameter-set analog value
H02: Analog value input from terminal
*1
Refer to the list of calibration parameters on the next page for
calibration parameters.
Write
HEC
*2
The gain frequency can also be written using Pr. 125 (instruction
code H99) or Pr. 126 (instruction code H9A).
Inverter Send Data
ACK 00
Set "H01" in the extended link parameter.
ACK 00
Set "H01" in second parameter changing.
STX 00 0000 ETX 25
C3 (Pr. 902) is read. 0% is read.
STX 00 0000 ETX 25
C6 (Pr. 904) is read. 0% is read.
Data Description
Communication
Data
H9696
H5A5A
H9966
H55AA
and later, link parameter expansion setting
Pr.100
*1
*2
Description
Number of
Data Digits
(format)
4 digits
(A,C/D)
parameters
4 digits
(A,C/D)
4 digits
(B.E/D)
4 digits
(A,C/D)
2digits
(B.E'/D)
2digits
(A',C/D)
2digits
(B.E'/D)
2digits
(A',C/D)

Hide quick links:

Advertisement

Table of Contents
loading