Mhouse MhouseKit WS2S Installation And User Manual

Mhouse MhouseKit WS2S Installation And User Manual

For power-operated swing gate
Hide thumbs Also See for MhouseKit WS2S:

Advertisement

MhouseKit WS2
S
For power-operated swing gate
Installation instructions and warnings, and User Manual
IS0004A00EN 28-03-2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MhouseKit WS2S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mhouse MhouseKit WS2S

  • Page 1 MhouseKit WS2 For power-operated swing gate Installation instructions and warnings, and User Manual IS0004A00EN 28-03-2011...
  • Page 3: Table Of Contents

    CONTENTS GENERAL SAFETY WARNINGS AND PRECAUTIONS MAINTENANCE STEP 9 STEP 1 PRODUCT DISPOSAL KNOWLEDGE OF THE PRODUCT AND PREPARATION FOR INSTALLATION STEP 2 FURTHER INFORMATION 2.1 - PRODUCT DESCRIPTION AND INTENDED USE STEP 10 2.2 - COMPONENTS USED TO SET UP A COMPLETE SYSTEM 10.1 - ADVANCED SETTINGS 10.2 - OPTIONAL ACCESSORIES PRELIMINARY CHECKS FOR INSTALLATION...
  • Page 4: General Safety Warnings And Precautions

    • This manual describes how to set up a complete and optimal 2.1 - PRODUCT DESCRIPTION AND INTENDED USE automation, such as that shown in fig. 1, using all Mhouse devices that are part of the automation system named “WS2S”. Some of The devices in this kit, plus other accessories (some optional and not these devices are optional and may not be present in the kit.
  • Page 5: Components Used To Set Up A Complete System

    3 - Ensure that the estimated lifetime is compatible with the intended use single 2-wire cable (“ECSbus” system). The control unit can also be mains-powered (230 V) or alternatively by the Mhouse PF photovoltaic (see paragraph 3.3). 4 - Ensure that all limits, conditions and warnings in this manual can be system.
  • Page 6: Step

    Fig. 1 shows a system made using this product and other optional accessories in the Mhouse b) - Refer to fig. 1 to check positions of the electrical cables in the area.
  • Page 7 English – 5...
  • Page 8: Installation: Assembly And Connection Of Components

    5.1 - INSTALLING THE GEARMOTOR WS1SC 01. Ensure that the fixing surface is perfectly smooth, level and sufficiently compact. WS2S is not supplied with fixing devices, which must be chosen also on the basis of the fixing surface material. 02. Prepare one or more duct tubes for routing the electric cables (fig. 6);...
  • Page 9 English – 7...
  • Page 10 Blue Yellow/Green Brown KS100 PH100 FL100 STOP OPEN FLASH FLASH ECS bus STOP OPEN Yellow/Green Blue Brown WS1SC WS1SK 8 – English...
  • Page 11: Step

    ––– STEP 6 ––– board. No polarity needs to be observed. 07. Fix the covering shell [D] of fig. 19-6 with the two screws [E] of fig. 19-6 using a Phillips screwdriver. Lastly, insert the external cover [F] 6.1 - INSTALLING AND CONNECTING PH100 in fig.
  • Page 12 A / B A / B A / B Ø = 6 mm Ø = 6 mm A / B A / B A / B A / B A / B A / B A / B A / B 10 –...
  • Page 13: Programming

    PROGRAMMING ––– STEP 7 ––– of the leafs. In this phase the system reads the leaf opening angle from the mechanical closing stop through to the mechanical opening stop. The presence of fixed and sufficiently strong mechanical stops is essential. 7.1 - POWER SUPPLY CONNECTION 01.
  • Page 14: Testing And Commissioning

    TESTING AND COMMISSIONING ––– STEP 8 ––– trol unit recognition of the event. 04. To test photocells and in particular that there is no interference with These are the most important phases when setting up an automation, in other devices, pass a cylinder (fig. 26) (diameter 5 cm, length 30 cm) order to guarantee maximum safety.
  • Page 15: Commissioning

    (use appendix 1).“EC declaration of conformity for com- ponents of WS2S”. 02. Affix a dataplate on the door, specifying at least the following data: type of automation, name and address of manufacturer (responsible MAINTENANCE –––...
  • Page 16 the keys must always be pressed and released slowly, pressing for at least on the gate. Excessive force settings may impair safety system opera- one second, releasing for one second and so on. tion or cause damage to the gate. •...
  • Page 17: Optional Accessories

    Press and hold T4 10.2 - OPTIONAL ACCESSORIES As well as the devices in WS2S, there are a number of optional acces- sories which may be used to integrate the automation system. PR1: 24 V buffer battery; in the event of a mains power failure, this guar- antees at least 10 complete cycles.
  • Page 18 The box contains the value of the severity 10.2.3 - Maximum possible number of cycles per day index (K) for each manoeuvre (e.g. WS2S with a leaf of 130 Kg and This product is specifically designed to operate also with the PF solar opening of 100°;...
  • Page 19: Adding Or Removing Devices

    8.2 kΩ constant resistance output will guarantee the fail-safe category 3. An automation using WS2S enables devices to be added or removed at any time. As with the ECSBus, the control unit recognises the type of device con- Caution! –...
  • Page 20: Memorizing All Radio Transmitters

    Unused jumpers must be placed in the special compartment for future use (fig. 33). 03. Carry out the learning phase as described in paragraph 10.3.3 “Re - cognition of other devices”. TABLE 8 Jumpers Photocell Jumpers Photocell Photocell on right with activa- Photocell h=50 cm;...
  • Page 21 TABLE 9 Once “OPEN” Command Activates the automation as described in Table 3 (Open function) Twice “Pedestrian opening” command Activates partial opening of one or two leafs as described in Table 3 (Pedestrian opening) Three times “Only open” command Activates opening of the leafs (open - stop - open etc.) Four times “Only close”...
  • Page 22: Troubleshooting

    10.5 - TROUBLESHOOTING 10.6 - DIAGNOSTICS AND SIGNALS Table 10 gives possible indications on how to deal with malfunctions that Some devices directly provide particular signals to describe the state of may be met during installation or due to a fault. operation or eventually a malfunction.
  • Page 23 10.6.2 - Segnalatore lampeggiante lampeggi con frequenza maggiore (mezzo secondo); i lampeggi si ripeto- no due volte, separati da una pausa di un secondo, vedere Tabella 12. Il segnalatore lampeggiante durante la manovra esegue un lampeggio ogni secondo; quando accadono delle anomalie, vengono emessi dei TABLE 12 Quick flashes Status...
  • Page 24 LED P1 [D] Status Action Off * Everything OK No memorisation underway Memorisation mode 1 This is normal during memorisation mode 1 which lasts maxi- mum 10 s. Series of quick flashes, Memorisation mode 2 This is normal during memorisation mode 2 which lasts maxi- from 1 to 4 mum 10 s.
  • Page 25: Technical Specifications Of Product Components

    TECHNICAL SPECIFICATIONS OF PRODUCT COMPONENTS The product WS2S is produced by Nice S.p.a. (TV) I, Mhouse is a company part of the NICE S.p.a. group. In order to improve its products, NICE S.p.a. reserves the right to modify the technical characteristics at any time without prior notice. In any case, the manufacturer guarantees their functionality and fitness for the intended purposes.
  • Page 26 Indicator light with 12V 21W lamp controlled by the control units for MHOUSE automations Lamp 12V 21W fitting BA15 (vehicle type lamp) Power supply The device can only be connected to the terminals “FLASH” and “AERIAL” of the MHOUSE automation control units Ambient operating temperature -20 ÷ 50°C...
  • Page 27 GTX4 Transmitters Product Type Radio transmitters for remote control of automations for automatic gates and doors. Adopted technology Encoded AM OOK radio modulation Frequency 433.92 MHz Encoding 64 Bit rolling code (18 billion billion combinations) Keys 4, each key can be used for different commands of the same control unit or to control different control units Radiated power 0.001 W approx.
  • Page 29 Declaration in accordance with the Directives: 1999/5/CE (R&TTE), 2004/108/CE (EMC); 2006/42/CE (MD) Appendix II, part B WS1SC, WS1SK, GTX4, PH100 and FL100 are produced by Nice S.p.a. (TV) I; MHOUSE S.r.l. is a commercial trademark owned by the group Nice S.p.a.
  • Page 30: User's Guide

    USER’S GUIDE ––– STEP 11 ––– • Suspend the use of the automation immediately as soon as you notice something abnormal in the operation (noises or jolting movements); failure to follow this warning may cause This guide must be stored safely and be accessible to all automa- serious danger and accidents.
  • Page 31: Maintenance Operations Admissible To The User

    05. To reset the automation turn the key clockwise and at the 11.5 – Remote control battery replacement same time move the gate until you hear the carriage engage. (fig. 41) 06. Remove the key and close the release cap cover by turning it When the battery charge is low, the transmitter range is reduced clockwise.
  • Page 33 APPENDIX 2 CE DECLARATION OF CONFORMITY In conformity with Directive 2006/42/EC, APPENDIX II, part A (EC declaration of conformity for machinery) –––––––––––––––––––– The undersigned/company (name or company name of the person responsible for commissioning of the power-ope- rated gate): ..................Address: .
  • Page 36 Mhouse is a commercial trademark owned by Nice S.p.a. Nice S.p.a. Via Pezza Alta, 13 - Z.I. Rustignè 31046 Oderzo (TV), Italia Tel. +39 0422 85 38 38 Fax +39 0422 85 35 85...

Table of Contents