Roof Termination Details – Direct Vent Installation; Ipex Concentric Termination (Roof); Polypro / Innoflue Roof Termination; Exhaust Only Roof Termination - NTI Trinity TX51 Installation And Operation Instructions Manual

Hide thumbs Also See for Trinity TX51:
Table of Contents

Advertisement

Tx I&O Manual
Roof Termination Details – Direct Vent Installation
Two-Pipe Termination (Roof)
Exhaust
Vertical
Min. 18"
Flashing
Horizontal
4-12" or greater
than 36"

PolyPro / InnoFlue Roof Termination

Refer to documentation included with termination kit for
complete installation instructions.
Min. 12"
above grade
or snow level
Figure 4-6(a)
Vent Screen
Vent pipe piece to
retain vent screen
Air-inlet
Min. 12"
above grade
or snow level
Figure 4-6(c)
Exhaust
Air-inlet
Flashing
Figure 4-6(b)

IPEX Concentric Termination (Roof)

Refer to documentation included with termination kit for
complete installation instructions.
Exhaust center
Air-inlet around
perimeter
Figure 4-6(d)

Exhaust only Roof Termination

Figure illustrates two options for exhaust termination only;
neither vent pipe illustrated is for combustion air-inlet.
Vent pipe piece to
retain vent screen
Vent Screen
Exhaust
Option 2
Flashing
│General Venting
Vent pipe piece to
retain vent screen
Vent Screen
Min. 12"
above grade
or snow level
Flashing
Exhaust
Option 1
Min. 12"
above grade
or snow level
21