Disassembly Procedures

High voltage is present at the high voltage terminal of
the high voltage transformer during any cooking cycle.
It is neither necessary or advisable to attempt
measurement of the high voltage.
Before touching any oven components or wiring, always
unplug the oven from its power source and discharge
capacitor.

Disconnecting Wire Terminals

All wire terminals are locking-type terminals.
Proceed as follows to disconnect wire terminals:
Insulated terminals:
Grasp insulator pod and pull back.
DO NOT PULL ON WIRE.
Non-insulated terminals:
Use a small blade screwdriver to depress locking-tab
and pull on terminal.
DO NOT PULL ON WIRE.
©2010 ACP Inc.
To avoid the risk of electrical shock, personal injury, or death,
disconnect power to oven and discharge the capacitors before
following any disassembly procedure.

Outer Case

1. Disconnect power to oven.
2. Remove screws securing outer case to unit.
3. Slide outer case towards rear of unit.
4. Reverse procedure to reassemble.
During disassembly some foam gaskets may require
removal. These components must be replaced for
proper circulation of air over the components and
through the oven cavity.