Component Testing Procedures - ACP RFS18TS Technical Information

Commercial microwave 208 / 240 v, 60 hz
Hide thumbs Also See for RFS18TS:

Advertisement

Component Testing Procedures

To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires it.
Illustration
Thermal cutout
Diode
Capacitor
Magnetron
Blower motor
Stirrer motor
Transformer
Secondary
Filament
Primary
Noise filter board
Circuit Protector
16500024
!
WARNING
Component
Disconnect all wires from TCO.
Measure resistance across terminals.
Cavity TCO ...........................................
Magnetron TCO ....................................
Discharge Capacitor
Remove diode lead from capacitor and
connect ohmmeter.
Reverse leads for second test.
Discharge Capacitor
Remove wires from capacitor terminals
and connect ohmmeter, set on highest
resistance scale to terminals.
Also check between each terminal and
capacitor case.
Discharge Capacitor
Remove wires from magnetron and
connect ohmmeter to terminals. Also
check between each terminal and
ground.
Remove all wires from motor.
Measure resistance across coil .............
Remove all wires from motor.
Measure resistance across terminals ....
Discharge Capacitor
Remove all wires from terminals.
Measure resistance from:
Primary ................................................
Filament ...............................................
Secondary to Ground screw on
transformer stack .................................
Power In terminals ................................
Power Out terminals..............................
Measure resistance across terminals ....
Testing
Opens at 230
Closed at 140
Infinite resistance should be
measured in one direction and 50K
or more in the opposite direction.
NOTE: Ohmmeter must contain a
battery of 6 volts minimum.
Between Terminals: Meter should
momentarily deflect towards zero
then return to over 5 M
deflection occurs, or if continuous
deflection occurs, replace capacitor.
Terminal to Case: Infinite resistance
Between Terminals: Less than 1
Each terminal to ground measures
Infinite resistance.
Note: This test is not conclusive. If
oven does not heat and all other
components test good replace the
magnetron and retest.
Approximately 28 – 35
Approximately 12 – 14 K
Less than <1
Less than <1
Approximately 70-80
240 VAC
240 VAC
If no power in, check power outlet.
If no power out, check fuses.
Between Terminals: Less than 1
2
Results
F (110
C)
°
°
F (60
C) and
°
°
Opens at 320
F (160
C)
°
°
. If no
October 2013
©2013 ACP, Inc.