CAN/CAN - Gateway
# PIDs for CAN channel 2
# CAN 2: 29-bit IN-Id: 0x6E
xpidin2 = x6E
# CAN 2: 29-bit OUT-Id: 0x1FFE
xpidout2 = x1FFE
name
For easier identification of the programmed
settings, the configuration can be labeled. The
configuration name must not have more than
32 characters and must not contain space cha-
racters or tabs. If this key is missing, no name
will be assigned to the configuration.
Example:
name = standard_configuration
deviceid
During the configuration process via CAN the
device has to be uniquely selected in the net-
work. This process is based on the serial num-
ber of the device.
If there is the need to have the configuration
process independent of the serial number, a
device id can be assigned. Then the identifica-
tion of the device depends on the device id
and not on the serial number.
Care must be taken to use a particular device
id just once in a network, if more than one ga-
teways is used.
The device id can have values between 1 and
99999999.
Example:
deviceid = 50