Specifications

Injector size (mm)
Burner Pressure (kPa)
Minimum Gas Pressure (kPa)
Maximum Gas Pressure (kPa)
Input (MJ)
Number of burners
Gas inlet connection
Header connection
Gas valve
Ignition module
Control board
45ºC inlet high limit
55ºC outlet high limit
Transformer
Pressure switch¹
Flow switch¹
40ºC temperature probe
Control circuit fuse
Relay 1²
Relay 2²
Reset illuminated push button
Flow Rate (l/s)
Power Supply
¹
The installation will have either a pressure switch or a flow switch depending upon the application (refer to
'Water Pressure Switch‟ on page 17 for more information).
²
Models manufactured from the 14/4/09 feature an integrated PCB with power outage auto reset
incorporating the relays.
Auxiliary Component Specifications
Component
Electrical Interface Board (E.I.B)
Note: Auxiliary components are optional and may not be installed.
TM018 Raypak 131 Type A Pool & Spa Heaters REV: A
D.O.I: 8/04/2009
This document is stored and maintained electronically by
Pre 2007
Post 2007
Campini TY60, opens 45ºC closes 35ºC (+/- 3ºC)
Secondary winding 24 Volts AC 50Hz 1.3 ohms
Barksdale MSPS-EE05-Q71 or Tecmark MSPS-EE05
Adjustable: 3.5 – 34.5kPa, max pressure 55kPa
Omron LY2N, DPDT, 24VAC, coil resist 186 ohms
Omron LY2N, DPDT, 24VAC, coil resist 186 ohms
Minimum
Maximum
Millennium 56659201 240VAC (30A max @ 240V)
Service. All printed copies not bearing this statement in RED are deemed "uncontrolled"
P0131NCO
1.36
0.85
1.13
White Rogers 36E06-301
White Rogers 36G22-216
RAM-H4M7-01
Millennium grey or black board (24VAC 50Hz)
36TXVG11, opens 55 ºC closes 45 (+/- 3ºC)
Primary winding 240 Volts AC 50Hz 62.2 ohms
Adjustable: max pressure 1000kPa
Refer to table on page 40
24VAC LED, 1 X N/O momentary contact
240VAC 50Hertz
4
P0131PCO
0.77
2.64
2.75
3.5
120
15
RP¾/20
40mm
3A
1.3
6.9

Advertisement