E-Ion Operation - Panasonic CS-E24LKES Service Manual

Indoor/outdoor unit
Hide thumbs Also See for CS-E24LKES:
Table of Contents

Advertisement

• Indicator
- When patrol is selected, patrol sensor indicator ON.
NO
1
2
3
4
5
• Remote Control Receiving Sound
• Normal Operation
• Patrol Mode
• Patrol Mode
• Stop
• Timer Control
- When ON timer activates when unit stops, previous operation resumes and restored last saved Patrol operation status.
- When ON timer activates during any operation, no change and carry on current operation.
- When OFF timer activates during any operation, all operation stops and the latest Patrol operation status is saved.
• Power Failure Control
- During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation resumes
immediately.
- During combination operation, if power failure occurs, after power resumes combination operation resume immediately.

12.9. e-ion Operation

A. Purpose
This operation provides clean air by producing negative ions to attract dust captured at the positively charged e-ion filters.
B. Control Condition
a. e-ion operation start condition
• During unit running at any operation mode, if "e-ion" operation is selected, combination operation (operation mode + e-ion
operation) starts.
• During unit is OFF, if "e-ion" operation is selected, e-ion individual operation starts.
b. e-ion operation stop condition
• When "OFF/ON" button is pressed to stop the operation.
• When "PATROL/e-ion" button is pressed.
• When OFF Timer activates.
c. e-ion operation pause condition
• When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after indoor fan restarts.
• When indoor intake temperature
minutes.
C. Control Content
a. Indoor fan control
• During any operation mode combines with e-ion operation, fan speed follows respective operation mode.
• During e-ion individual operation - only Auto Fan Speed and no Powerful operation is allowed. Even if Fan Speed button is
pressed, no signal is sent to air conditioner, and no change on LCD display.
Description
When patrol is selected function is not selected
During gas sensor error detection control
During stop
2 minutes gas sensor initial stabilization time (Level 0)
During operation
During patrol
Patrol Mode
:
Beep
Stop
:
Long Beep
Normal Operation
:
Beep
Patrol
:
Beep
40°C. e-ion operation resume after indoor intake temperature < 40°C continuously for 30
a. Dirtiness level 0*
b. Dirtiness level 1
c. Dirtiness level 1*
d. Dirtiness level 2
40
BLUE
E-ION
OFF
-
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON