E-Ion Operation - Panasonic CS-C12HKF Service Manual

Table of Contents

Advertisement

12.14. e-ion Operation

• This operation provides clean air by producing negative ions to attract dust captured at the positively charged e-ion filters.
• e-ion operation start condition
- During unit running at any operation mode, if "e-ion" button is pressed, combination operation (operation mode + e-ion
operation) starts.
- During unit is OFF, if "e-ion" button is pressed, e-ion individual operation starts.
• e-ion operation stop condition
- When "OFF/ON" button is pressed to stop the operation.
- When "e-ion" button is pressed again.
- When "Patrol" button is pressed.
- When OFF Timer activates.
• e-ion operation pause condition
- When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after indoor fan restarts.
- When indoor intake temperature
minutes.
• Indoor fan control
- During any operation mode combines with e-ion operation, fan speed follows respective operation mode.
- During e-ion individual operation - only Auto Fan Speed and no Powerful operation is allowed. Even if Fan Speed button is
pressed, no signal is sent to air conditioner, and no change on LCD display.
Auto Fan Speed for e-ion operation switches between HLo and CLo at pattern below:
40°C. e-ion operation resume after indoor intake temperature < 40°C continuously for 30
36

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-c12hkf

Table of Contents