15.4. Error Codes Table
Diagnosis
Abnormality or Protection Control
Display
H00
No memory of failure
H11
Indoor / outdoor abnormal
communication
H12
Indoor unit capacity unmatched
H14
Indoor intake air temperature sensor
abnormality
H15
Compressor temperature sensor
abnormality
H16
Outdoor current transformer (CT)
abnormality
H19
Indoor fan motor merchanism lock
H23
Indoor heat exchanger temperature
sensor abnormality
H25
Indoor E-Ion abnormality
H27
Outdoor air temperature sensor
abnormality
H28
Outdoor heat exchanger temperature
sensor 1 abnormality
H30
Outdoor discharge pipe temperature
sensor abnormality
H32
Outdoor heat exchanger temperature
sensor 2 abnormality
H33
Indoor / outdoor misconnection
abnormality
H34
Outdoor heat sink temperature sensor
abnormality
H36
Outdoor gas pipe temperature sensor
abnormality
Abnormality
Protection
Judgement
Operation
—
Normal operation
After operation for
Indoor fan only
1 minute
operation can start
by entering into
force cooling
operation
90s after power
—
supply
Continuous for 5s
—
Continuous for 5s
—
—
—
Continuous
—
happen for 7 times
Continuous for 5s
—
Port is ON for 10s
—
during E-Ion off
Continuous for 5s
—
Continuous for 5s
—
Continuous for 5s
—
Continuous for 5s
—
—
—
Continuous for 2s
—
Continuous for 5s Heating protection
operation only
56
Problem
Check Location
—
• Indoor / outdoor
• Indoor / outdoor wire
communication not
terminal, indoor /
establish
outdoor PCB, indoor /
outdoor connection
wire
• Total indoor
• Indoor / outdoor
capability more than
connection wire,
maximum limit or less
indoor / outdoor PCB,
than minimum limit,
specification and
or number of indoor
combination table in
unit less than two
catalogue
• Indoor intake air
• Indoor intake air
temperature sensor
temperature sensor
open or short circuit
lead wire and
connector
• Compressor
• Compressor
temperature sensor
temperature sensor
open or short circuit
lead wire and
connector
• Current transformer
• Outdoor PCB faulty
faulty or compressor
or compressor faulty
faulty
• Indoor fan motor lock
• Fan motor lead wire
or feedback
and connector, fan
abnormal
motor lock or block
• Indoor heat
• Indoor heat
exchanger
exchanger
temperature sensor
temperature sensor
open or short circuit
lead wire and
connector
—
• E-Ion PCB
• Outdoor air
• Outdoor air
temperature sensor
temperature sensor
open or short circuit
lead wire and
connector
• Outdoor heat
• Outdoor heat
exchanger
exchanger
temperature sensor 1
temperature sensor 1
open or short circuit
lead wire and
connector
• Outdoor discharge
• Outdoor discharge
pipe temperature
pipe temperature
sensor open or short
sensor lead wire and
circuit
connector
• Outdoor heat
• Outdoor heat
exchanger
exchanger
temperature sensor 2
temperature sensor 2
open or short circuit
lead wire and
connector
• Indoor and outdoor
• Indoor and outdoor
rated voltage
units check
different
• Outdoor heat sink
• Outdoor heat sink
temperature sensor
sensor
open or short circuit
• Outdoor gas pipe
• Outdoor gas pipe
temperature sensor
temperature sensor
open or short circuit
lead wire and
connector
—