13.14

E-ion operation

This operation provides clean air by producing negative ions to attract dust captured at the positively charged
active e-ion filters.
e-ion operation start condition
During unit running at any operation mode, if "e-ion" operation is selected, combination operation (operation
o
mode + e-ion operation) starts.
During unit is OFF, if "e-ion" operation is selected, e-ion individual operation starts.
o
e-ion operation stop condition
When "OFF/ON" button is pressed to stop the operation.
o
When "PATROL/e-ion" button is pressed.
o
When OFF Timer activates.
o
e-ion operation pause condition
When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after
o
indoor fan restarts.
When indoor intake temperature ≥ 40°C. e-ion operation resume after indoor intake temperature < 40°C
o
continuously for 30 minutes.
Indoor fan control
During any operation mode combines with e-ion operation, fan speed follows respective operation mode.
o
During e-ion individual operation – only Auto Fan Speed and no Powerful operation is allowed. Even if Fan
o
Speed button is pressed, no signal is sent to air conditioner, and no change on LCD display.
Auto Fan Speed for e-ion operation switches from SHi to Hi after 4 hours of operation.
Airflow direction control
During any operation mode combines with e-ion operation, airflow direction follows respective operation
o
mode.
During e-ion individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no
o
signal is sent to air conditioner, and no change on LCD display.
Timer control
When ON timer activates when unit stops, previous operation resumes and restored last saved e-ion
o
operation status.
When ON timer activates during any operation, no change and carry on current operation.
o
When OFF timer activates during any operation, all operation stops and the latest e-ion operation status is
o
saved.
Indicator
When e-ion operation starts, e-ion indicator ON.
o
Remote Control Receiving Sound
Normal Operation
o
e-ion Operation
o
Stop
o
e-ion individual Operation
o
Power failure
During e-ion individual operation, if power failure occurs, after power resumes, e-ion individual operation
o
resumes immediately.
During combination operation, if power failure occurs, after power resumes, combination operation resume
o
immediately.
e-ion operation status is not memorized after OFF the unit. After OFF, when the operation is ON again, air
o
conditioner operates without e-ion operation.
e-ion Operation
Normal Operation
e-ion individual Operation
Stop