TRBL
ANLS

TROUBLESHOOTING

Error content
Communication cable
related error occurs
Application does not
start
Application related error
occurs
Database related error
occurs
Incorrect fonts on
screen
When executing the sta-
tionary test or active test
the test cannot be
ended even if the Can-
cel is clicked.
TROUBLESHOOTING
Cause
Communication cable is discon-
nected.
Battery is disconnected from the
watercraft.
The battery voltage is below 12 V.
The hardware does not meet the
requirements to operate this
application.
YDIS.exe is not installed in appli-
cation directory.
Other application (Service tool) is
already in operation.
Error message "Program file or
Database file is not installed
properly. Please install again." is
displayed.
Error message "Database files
are not installed properly. Please
update again." is displayed.
Error message "System file not
found ######.###." is displayed.
The computer language does not
correspond to the application.
Execute and Cancel buttons have
been clicked more than neces-
sary, and the ECM or PC does
not operate properly.
Connect communication cable
between the computer's commu-
nication port and 3-pin communi-
cation coupler of the watercraft.
Connect battery to watercraft.
Connect battery of 12 V or higher.
Use a computer that meets the
specified hardware requirements.
If YDIS.exe is not found in the
application directory, install the
application again.
Quit the application in operation,
since two applications (Service
tool) cannot be operated simulta-
neously.
Install program file or database
file again.
Update database again.
The database is not applicable to
communication with ECM.
Update database to correspond
to ECM.
Use a computer that operates the
required operating system.
Turn off your PC.
Push the engine stop switch and
reset the ECM.
9-50