r--------------------------~------~--------------------------~
DRAIN WATER HOSE
To install the
drain water
hose, follow these
steps:
~
1.
Drill
a
hole
through
flooring. It
is essential that
it
is
drilled in
the cut
out
opening of the base plate at the
rear of the refrigerator.
2. Make sure that the
hose
does
not kink when run
through the floor.
3. Seal around the hose
that
goes
through
the
drilled
hole.
If a
longer
hose
than supplied
is required, the
installer needs to supply one
in order
for the
water
to
drain
outside of the
vehicle.
GAS CONNECTION
(NDA1402)
Hook up to the gas supply line is
accomplished
at the
manual
gas
valve,
which is
furnished
with a 3/8" SAE (UNF 5/8" -18)
male
flare
connection.
All
completed
connections
should be
checked for
leaks
with
a non corrosive
commercial
bubble
solution.
A
WARNING
EXPLOSION
HAZARD. Never
use an open
flame
to check for gas leaks.
Failure
to heed this warn-
ing could
cause
an explosion resulting in death or
severe personal injury.
The gas supply system must incorporate a pressure
regulator
to
maintain
a supply pressure
of
not more
than It
inches
water
column.
When testing the gas supply system at test
pressures:
112psi
-
the refrigerator and its individual shutoff valve
must be
disconnected
from the gas supply piping system.
• ~ 112psi
-
the appliance
must
be isolated from the gas
supply piping
system
by closing its
individual manual
shut-
off valve.
For
detailed instructions on the
installation and
connection to
the gas supply, contact
your
dealer
or
distributor.
TESTING LP GAS SAFETY SHUT
OFF
The gas safety shut off must be tested
after
the refrigerator is
connected to LP gas supply. To test the gas safety shut
off,
fol-
low these steps:
~
1.
Turn on
the
refrigerator
and
switch
to GAS mode.
2. Check
that
the GAS indicator dot is illuminated
and
the gas flame
is
lit.
3. Close the manual gas shut off valve at the back of
the refrigerator.
4. Wait for approx.
6-7
minutes.
The message
"ch LP" is displayed
(flashing).
5.
Remove the
protection
cover.
6.
Open the
manual
gas
shut
off valve. (Do
not
change
any button positions on the control panel.)
7. Apply a
non
corrosive commercial bubble
solution
to the
burner
jet
orifice.
No bubbles
should
appear at
the opening of the burner jet
orifice.
The presence of
bubbles indicates a defective gas safety shut off,
and
service is
required.
8. If
no bubbles
were present
at
the burner
jet
orifice,
rinse it with fresh water. Be careful
not
to damage
the burner
jet
orifice.
9. Put back the cover.
10. Switch the refrigerator OFF and back ON again.
Normal
operation
of the burner
should
return.
11.
Allow the
burner to operate
for a minimum of
5
minutes
ELECTRICAL
CONNECTION
120VAC CONNECTION
The refrigerator is equipped with a three-prong (grounding)
plug for your protection against
shock
hazards
and
should be
plugged directly into a properly
grounded
three prong
recep-
tacle.
DO
OT cut or remove the grounding prong from this
plug!
The free length of the cord is 2 feet and
it
is
recommended that
the receptacle is located to the right side of the
refrigerator
(viewed from the rear).
The receptacle should be
3"
(from
the bottom of the plastic receptacle)
above the refrigerator
mounting
floor.
This allows easy access through the
vent
door.
The cord should be
routed
to avoid direct contact with
com-
ponents
that could
damage the
cord
insulation.
3"
12V
DC CONNECTION
The
refrigerator
requires a continuous 12 V DC supply to
main-
tain the automatic energy selector system
and
the auto
defrost
control system to
function.
The connection is made to the positive (+)
and
negative (-)
terminals ofthe
terminal
block on the back of the refrigerator.
Correct polarity must be
observed when
connecting to the DC
supply.
Do not use the chassis or vehicle frame as one of the
conductors. Connect two wires at the
refrigerator and
route to
the DC supply.
Maximum
fuse
size for the
DC
supply
is
lOA.