Drain Water Hose; Connections - Dometic RM 2355 Installation And Operating Instructions Manual

Refrigerator for lp-gas and electric operation
Table of Contents

Advertisement

b)
Once the lower front strip is slipped
under the hinge, the part is possible to
swing into place as shown in Fig. 13.
c)
Secure the refrigerator and the lower
front strip with two screws: One screw
through the hinge, and on the opposite
side and then, one screw through the
lower front strip, see Fig. 13.
2.
Two screws installed in the top frame.
a)
Remove the top decoration panel. Open
the door and gently push the tabs out of
the hole in the hinge with a flat blade
screwdriver, (both sides), see Fig. 14.
RM 2455
RM 2555
RM 4605
b)
Carefully tilt the top decoration panel
and lift up to remove from top frame.
Be careful not to damage the circuit
board and wires.
c)
Install the two screws in the top frame,
the holes are accessible from under-
neath.
d)
Seal the opening for the screws with
aluminium tape.
e)
Replace the top decoration panel. Be
careful not to pinch the wires behind the
panel. Make sure the tabs snap back into
the holes in the hinge plate.
3.
Two screws installed in the rear base, see
Fig. 15.
3
2
Fig. 14
1
Fig. 15

DRAIN WATER HOSE

A hole must be drilled
through flooring see
Fig. 16 / 17.
The installer has to
make sure that the hose
does not kink when run
through the floor. Seal
around the hose that
goes through the drilled
hole.
Fig. 13
���� ��� ����� ����� ����

CONNECTIONS

LP GAS CONNECTION
The refrigerator is designed for operation on LP gas (Propane).
NOTE! Alternative gas types must not be used to operate
this appliance!
The gas supply system must incorporate an approved gas pres-
sure regulator to maintain a supply pressure of 2.75 kPa. The
test point pressure must be 2.70 kPa. Check that this is stated
on the data plate.
CAUTION! Check that the gas supplied to the refrigerator
is at the correct pressure.
The gas installation and servicing must be carried out by an
authorised person and conform to gas fitting regulations.
The appliance shall be installed in accordance with AS 5601-
Gas Installations.
The gas supply pipe should be connected to the gas inlet con-
nection at the rear of the refrigerator by means of a suitable
threaded coupling.
The connection nipple is furnished with an ISO 7/1 - Rp 1/8
internal pipe thread connection.
In making the connection to the refrigerator, a union gas cock
of an approved type bottled gas must be incorporated in the
supply line in a position that is readily accessible to the user.
For eventual servicing purposes, the union should be on the
outlet side of the cock and the pipework should be positioned
so as not to prevent the refrigerator from being readily
withdrawn.
Before leaving, the installer should:
Check all connections for gas leaks with soap and water.
DO NOT use a naked flame for detecting leaks!
Ignite the burner to ensure correct operation of gas valve,
burner and ignition.
Instruct the user on the correct method of operation. In case
the appliance fails to operate correctly after all checks have
been carried out, contact the authorised service provider in
your area.
12
���� ��� ����� ����� ����
If a longer hose than
supplied is required to
get the water to drain
outside of the vehicle,
the installer will have to
supply the extra length
of hose.
Fig. 17
RM 2455
RM 2555
RM 4605
Fig. 16
RM 2355

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rm 2555Rm 4605Rm 2455Rm 2555Rm 4605

Table of Contents