1
FIG. 9
Replace the top decoration panel. Be careful not to pinch
the wires behind the panel.
Make sure the tabs snap back into the holes in the hinge
plate.
STEP 3: Two screws installed in the rear base.
See FIG. 10.
Failure to follow the sequence in securing refrigerator in
enclosure can cause leakage between the frame and
cabinet. Any space between the counter, storage area
or ceiling and top of the refrigerator greater than 1-1/2
inches should be blocked. The heat produced at the rear
of the refrigerator will become trapped in this space,
making the top of the refrigerator hot and reduce the
efficiency of the refrigerator.
Hole for drain water hose
FIG. 10

Drain water hose

A hole must be drilled through flooring see FIG. 10.
The hole must be drilled in the cut out opening of the
base plate at the rear of the refrigerator. The installer
MUST make sure that the hose does not kink when run
through the floor. Seal around the hose that goes
through the drilled hole. If a longer hose than supplied is
required to get the water to drain outside of the vehicle,
the installer will have to supply the extra length of hose.
GAS CONNECTION
Hook-up to the gas supply line is accomplished at the
manual gas valve, which is furnished with a 3/8" SAE
(UNF 5/8" -18) male flare connection. All completed
connections should be checked for leaks with soapy
water.
2
DO NOT use a flame to check for gas leaks.
The gas supply system must incorporate a pressure
regulator to maintain a supply pressure of not more than
11 inches water column.
When testing the gas supply system at test pressures in
excess of 1/2 psig, the refrigerator and its individual
shutoff valve must be disconnected from the gas supply
piping system.
When testing the gas supply system at pressures less
than or equal to 1/2 psig, the appliance must be isolated
from the gas supply piping system by closing its individual
manual shutoff valve.
In case detailed instructions on the installation and
connection to the gas supply are required, contact your
dealer or distributor.
TESTING LP GAS SAFETY
SHUTOFF
The gas safety shutoff must be tested after the re-
frigerator is connected to the LP gas supply.
To test the gas safety shutoff, proceed as follows:
1.
2.
3.
4.
5.
6.
7.
! WARNING
Start the refrigerator according to the instructions
without connecting to 120 volts AC.
Check that the gas flame is lit. In AUTO, mode the
AUTO mode indicator lamp (A) is on.
Close the manual gas shut-off valve at the back of
the refrigerator. (See FIG. 1).
Wait for one minute. The CHECK indicator lamp (B)
should be on, and the flame extinguished.
Remove protection cover (see FIG. 1) and open the
manual gas shut-off valve. Do not change any button
positions on the control panel. Apply a non-corrosive
commercial bubble solution to the burner jet orifice.
No bubbles should appear at the opening of the
burner jet orifice. The presence of bubbles indicates
a defective gas safety shut-off and service is requi-
red.
If no bubbles were present at the burner jet orifice, it
should be rinsed with fresh water. Be careful not to
damage the burner jet orifice. Replace cover and
press the main power ON/OFF button (1) OFF and
back ON. Normal operation of the burner should
return. Allow the burner to operate for a minimum of
five minutes.
7