Service Mode; Setting The Test Mode; Emergence Memory Address; C Page Emergence Memory Address - Sony DCR-TRV120 Service Manual

Digital8 digital video cassette recorder
Hide thumbs Also See for DCR-TRV120:
Table of Contents

Advertisement

4-3.

SERVICE MODE

Additional note on adjustment
Note: After the completion of the all adjustments, cancel the service
mode by either of the following ways.
1) After data on page: D and F is restored, unplug the main
power supply and remove the coin lithium battery. (In
this case, date and time and menu setting have been set
by users are canceled. Perform resetting.)
2) After data on page: D and F is restored, select page: 0,
address: 01, and return the data to 00. And when data on
page: 2 and 3 are changed, return data to the original
condition.

1. Setting the Test Mode

Page F
Address 22
Data
80
Normal
81
Test mode
Various emergency prohibitions and releases
Drum emergency, capstan emergency, loading motor
emergency, reel emergency, tape top and end, DEW
detection
Page D
Address 10
Data
00
Normal
01
Forced camera power ON
02
Forced VTR power ON
03
Forced camera + VTR power ON
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page D and F, the data set will be recorded in the non-volatile
memory by pressing the PAUSE button of the adjustment remote
commander. In this case, take note that the test mode will not be
exited even when the main power is turned off (8.4 Vdc).
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjustment
remote commander. And select page: 0, address: 01, and set data:
00.
Function
Function

2. Emergence Memory Address

2-1. C Page Emergence Memory Address

Page C
Address
F4
EMG code when first error occurs
F6
Upper: MSW code when shift starts when first error
occurs
Lower: MSW code when first error occurs
F7
Lower: MSW code to be moved when first error
occurs
F8
EMG code when second error occurs
FA
Upper: MSW code when shift starts when second
error occurs
Lower: MSW code when second error occurs
FB
Lower: MSW code to be moved when second error
occurs
FC
EMG code when last error occurs
FE
Upper: MSW code when shift starts when last error
occurs
Lower: MSW code when last error occurs
FF
Lower: MSW code to be moved when last error
occurs
When no error occurs in this unit, data "00" is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency address
(F4 to F7). In the same way, when the second error occurs, the data
corresponding to the error is written in the second emergency address
(F8 to FB).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (FC to FF).
Note: After completing adjustments, be sure to initialize the data
of addresses F4 to FF to "00".
Initializing method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: C, address: F4, set data: 00, and press the PAUSE
button.
3)
Select address: F5 to FF and set data "00" into them in the
same way as address: F4.
4)
Select page: 0, address: 01, and set data: 00.
5-57
Address F4 to FF
Contents