DA20-C1 Flight Manual

7.11. ELECTRICAL SYSTEM

Simplified Schematic (see Figure 7.7)

7.11.1. Power Supply

A 12 V battery is connected to the master
bus via the battery circuit breaker (50
Amps). The 40 amp. generator is attached
to the engine near the propeller hub. The
generator feeds the main bus via the
generator circuit breaker (50 Amps). Both
circuit breakers can be triggered manually.
The generator warning light is activated by
an internal voltage regulator monitoring
circuit and illuminates when a generator
fault occurs.

7.11.2. Ignition System

The
engine
is
independent ignition systems.
magnetos are independent from the power
supply system, and are in operation as soon
as the propeller is turning and the ignition
switch is not off. This ensures safe engine
operation even in case of an electrical
power failure.
IF THE IGNITION KEY IS TURNED TO L, R OR BOTH, THE
RESPECTIVE MAGNETO IS "HOT". IF THE PROPELLER IS
MOVED DURING THIS TIME THE ENGINE MAY START AND
CAUSE SERIOUS OR FATAL INJURY TO PERSONNEL. THE
POSSIBILITY OF A 'HOT' MAGNETO MAY EXIST DUE TO A
FAULTY SWITCH OR AIRCRAFT WIRING.
CARE AND RESPECT WHEN IN THE VICINITY OF A
PROPELLER!
Doc # DA202-C1
Revision 25
provided
with
two
The two
WARNING
April 06, 2010
Figure 7.7. Simplified Schematic
USE EXTREME