RH-53/54
8-System Module
GenIO20
Soft Right
GenIO21
*
GenIO25
Up
GenIO27
1
GenIO28
Left
GenIO13
#
P00
Send
P01
3
P02
9
P03
8
P04
Down
P10
6
P11
4
P12
Right
P13
5
P14
Soft Left
P15
2
UEM Pin
PwrOnX
End / power
on/off
NOTES:
• Key number "#" is located on GenIO13 with interrupt on GenIOInt1. RH-53 Mar-
keting accept the reduction in performance when there is no wake up from deep
sleep.
• Power on/off and End Call are combined. For ending call: "short" keypress. For
power off: "Long" keypress
All lines are configured as input, when there is no key pressed; the inputs are high due to that
the UPP has internally pull-up resistors on those lines. When a key is pressed, the specific line
where the key is placed is pulled low. This generates an interrupt to the MCU and the MCU now
starts its scanning procedure.
Issue 2 06/2005
In
Up
In
Up
In
Up
In
Up
In
Up
In
Up
In
Up
In
Up
In
Up
In
Up
In
Up
In
Up
In
Up
In
Up
In
Up
In
Up
In
Up
In
Current source
Pull up
COMPANY CONFIDENTIAL
Copyright © 2005 Nokia. All Rights Reserved.
Nokia Customer Care
GenIOInt2
Falling edge interrupt
GenIOInt3
Falling edge interrupt
GenIOInt4
Falling edge interrupt
GenIOInt6
Falling edge interrupt
GenIOInt7
Falling edge interrupt
GenIOInt1
Falling edge interrupt
P0 int
Falling edge interrupt
P0 int
Falling edge interrupt
P0 int
Falling edge interrupt
P0 int
Falling edge interrupt
P0 int
Falling edge interrupt
P1 int
Falling edge interrupt
P1 int
Falling edge interrupt
P1 int
Falling edge interrupt
P1 int
Falling edge interrupt
P1 int
Falling edge interrupt
P1 int
Falling edge interrupt
INT on UPP