Introduction Introduction User Information The alarm system is a passive security product and has been conceived Warranty as a deterrent. Additional measures are necessary to prevent and hinder burglary and theft. You can obtain all the necessary information on this Dear Customer, from your local police station.
In such cases, contact your sales outlet, with your Large LC display, 1 numeric line in 7 segments for 24 characters, purchase receipt to hand, or the OLYMPIA service centre. 1 alphanumeric line in 5x7 dot matrix for 13 characters, 9 icons as...
Safety Information Safety Information Important Safety Information Please observe the following safety information to ensure the wireless Significance of the Symbols alarm system can be used safely and reliably: WARNING: Indicates potentially dangerous situations If you are uncertain or have any doubts about the functioning meth which could lead to fatal or severe personal od of the equipment during assembly and installation, contact a injury if the information is ignored.
Installation Installation, Base Unit Preparing and Connecting the Base Unit NOTE: The alarm system can also be operated without Information on Selecting the Installation Location a telephone connection. In the event the alarm is triggered, however, the internal telephone The base unit should be installed or positioned in a central location dialling unit is not activated! (e.g.
Installation Positioning the Base Unit Wall Installation It is possible to setup the device in a user-friendly, inclined position on a After having found a suitable location for the base unit, you can begin with table or desk. To do this, insert the two legs (1) supplied in the recesses for the installation.
Operating Elements and Indicators Operating Elements and Indicators Function Assignment to Buttons, Base Unit The base unit is equipped with an SOS (emergency call) button for emer gency situations and a Panic button in the event of a direct threat. The wireless remote control unit is provided with a button which can be con...
Operating Elements and Indicators Display Icons At Home mode: The system is armed; on burglary, the acoustic alarm signal is issued 0-9, *, # Digit keys: On pressing the # button >3 sec., a 2 sec. dialling pause is activated In Text mode: Switch between upper and lower case à...
Operating Elements and Indicators Function Assignment to Buttons, Remote Control Save icon Battery indicator Battery capacity of base unit is low. Overview of LEDs With power supply Without power supply Top LED Bottom LED Top LED Bottom LED (red) (yellow) (red) (yellow) Silent mode...
Menu Structure Menu Structure Review Open Sensor01 Voice Record Remote:1 Voice Record Register Search… Open Sensor01 Voice Record Remote:1 Voice Record Trigger Delay Delay: 0-240S Duration Trigger Tone Arming Delay Delay: 0-240S Flood & Smoke Standard Activate Remote Key Remote: SOS Remote: PANIC Entry Code 1234 OPERATING...
Page 14
Menu Structure Key Tone Key Tone-On Key Tone-Off Contrast Contrast-1-5 Language Deutsch Español Nederlands Dansk Português English Français Date/Time 01-01-2010 00:00 Alarm period Time:1-10Min OPERATING INSTRUCTIONS Page...
Configuration Configuration Selecting the Language There is a range of languages available for selection: General Information 1. Enter the device-specific Entry Code. Confirm it by pressing O. 2. The menu is opened by pressing the Menu button A briefly. NOTE: Before beginning to operate the base unit, de...
Configuration Setting the Date/Time 6. Text or numbers which have been entered can be deleted by press ing the D button. 1. Enter the device-specific Entry Code. Confirm it by pressing O. 7. Voice Record appears in the display. Confirm it by pressing 2.
Configuration Memory locations 0-9 (buttons 0 to 9) are available to enter up Activating the Internal Telephone Dialling Unit to 10 phone numbers. Each phone number can be composed of up to 24 with OGM Function characters/digits. In addition, a name with up to 13 characters/letters can The internal telephone dialling unit is deactivated if no telephone numbers be assigned to each phone number.
Configuration After having entered phone numbers, ensure that they are correct in re Saving an SOS (Emergency Call) Number spect of the alarm calls. You can do this by triggering a silent alarm. The You can save an SOS (emergency call) number which is subsequently telephone numbers you have entered are dialled in succession in the pro...
Configuration Trigger Delay Arming Delay The alarm is triggered after a delay so that if someone enters through the You can set an activation delay between 0 and 240 seconds. The alarm main door, they can disarm the alarm system before the acoustic alarm system is armed after this period has expired.
Configuration Alarm Period Key Tone On/Off The base unit is equipped with an integrated siren. The duration of the It is possible to switch the key tone feature for the base unit on and off: acoustic alarm can be selected between a minimum of 1 minute to a max 1.
Configuration Remote Control Flood and Smoke Detectors You can set-up the base unit so that flood and smoke detectors trigger an alarm when the base unit is disarmed. 1. Enter the device-specific Entry Code. Confirm it by pressing O. 2. The menu is opened by pressing the Menu button A briefly. 3.
Monitoring Functions Overview of Monitoring Functions Switching the Monitoring Functions On/Off NOTE: Before switching any functions on, inform all Monitoring Acoustic Internal telephone dialling the other people living in the residence regard function alarm signal unit activated ing the location and method of operation of the wireless alarm system.
Monitoring Functions You can define the required type of alarm as follows using either the base At Home Mode unit or the remote control unit supplied: NOTE: During the night, when you are asleep, you NOTE: If an outdoor siren is registered on the base should activate At Home mode.
Monitoring Functions Disarmed Mode Emergency Call (SOS) You can trigger the SOS (emergency call) function by pressing the S NOTE: When the system is disarmed, you can move freely within the living quarters without trigger button on the base unit or the button on the remote control unit, de...
Remote Access Via Telephone Remote Access Via Telephone Function The wireless alarm system can be operated by remote access using a Activate the handsfree function telephone. You can use a telephone to activate or deactivate the alarm Activate the screening function (in the system and switch the handsfree and screening functions on.
Resetting the Factory Settings (RESET) Resetting the Factory Settings (RESET) NOTE: Please note that when carrying out a RESET, all the user settings are deleted. The registra tion of the sensors is retained! After a RESET has been executed, the 4-digit Entry Code is 1-2-3-4! Proceed as follows to reset the factory settings on the wireless alarm sys...
5. Open Sensor01 or SmokeSensor01 appears in the display. You can the following web site rename the sensor, if necessary. Confirm it by pressing O. www.olympia-vertrieb.de 6. Voice Record appears in the display. Press C to retain the standard message or press O to record an individual message.
Changing the Batteries Changing the Batteries Remote Control 1. Use a precision screwdriver to loosen the screw in the battery com If the battery charge of the sensors is low or practically empty, the following partment on the underside of the wireless remote control. status messages appear in the display: 2.
Regular Maintenance and Servicing Regular Maintenance and Servicing Base Unit 1. Disconnect the base unit from the power outlet before cleaning it! 2. Clean the surface of the housing with a soft, lint-free cloth. Never use any chemicals or scouring agents. NOTE: Never immerse the equipment in water! OPERATING...
Information on Disposal Information on Disposal The implementation of European law in national laws and direct ives obliges you to dispose of consumable goods appropriately. This serves to protect both persons and the environment. The adjacent symbol indicates that electrical and electronic apparat us and batteries no longer required must be disposed of separ...
Technical Data Technical Data Remote Control Weight: ....24 g The wireless alarm systems in the Protect 6XXX-Series operate within the Dimensions (WxHxD): ..(40 x 60 x 14.5) mm frequency band specially reserved for security technology in the 868 MHz frequency range.
CE-Mark CE Mark The device fulfils the requirements stipulated in the EU Directive: 1999/5/EC (R&TTE) The CE Mark on the device confirms conformity. OPERATING INSTRUCTIONS Page...
Page 36
Keep this operating manual in a safe place away from the wireless alarm system! Please note that the Copyright of this operating instruction manual is by Olympia and, therefore, must not be further copied, published or sold in any form. The information contained in the operating instruction manual is only intended for personal use.
Need help?
Do you have a question about the Protect 6XXX Series and is the answer not in the manual?