Heater & Ventilation; Atf Level; Power Steering Fluid Level; Water Leak Test - Subaru 2004 FORESTER Service Manual

General information
Hide thumbs Also See for 2004 FORESTER:
Table of Contents

Advertisement

PRE-DELIVERY INSPECTION
6) Set the AT select lever to each gear position
while checking that the demanded gear position is
correctly attained.
(1)
(1) RHD model
(2) LHD model
Selector
Position
1st
D
OK
3
OK
2
OK
1
OK
39.HEATER & VENTILATION
Operate the heater and ventilation system to check
for normal airflow outlet control, air inlet control, air-
flow capacity, and heating performance.
40.AIR CONDITIONER
Operate the air conditioner. Check that the A/C
compressor operates normally and enough cooling
is provided.

41.ATF LEVEL

Check that the ATF level is normal. If insufficient,
check that no leaks are found. Then add the neces-
sary amount of the specified ATF.
(A)
(A) Level gauge
(B) Check position when "HOT"
(C) Upper level
(D) Lower level
(E) Check position when "COLD"
Pre-delivery Inspection
P
R
N
D
3
2
1
(2)
PI-00112
Gear Position
2nd
3rd
4th
OK
OK
OK
OK
OK
OK
(C)
(B)
(D)
(C)
(E)
(D)
PI-00105

42.POWER STEERING FLUID LEVEL

Check that the power steering fluid level is normal.
If insufficient, check that no leaks are found. Then
add the necessary amount of the specified power
steering fluid.
(A)
(C)
(A) Reservoir tank
(B) MIN level
(C) MAX level
43.FLUID LEAK CHECK
Check the entire areas of the vehicle for any trace
of coolant/oil/fluid leaks.

44.WATER LEAK TEST

Spray the vehicle with water and check that no wa-
ter enters the passenger compartment.
• Before performing the water leakage test, re-
move anything that may obstruct the operation or
which must be kept dry.
• Close all windows completely, and then close all
doors tightly. Close the hood before starting the
test.
• Connect a hose to a tap, and spray water on the
vehicle. The rate of water discharge must be ap-
prox. 20 — 252 (5.3 — 6.6 US gal, 4.4 — 5.5 Imp
gal) per minute.
When spraying water on areas adjacent to the floor
and wheel house, increase the pressure. When di-
recting water on areas other than the floor portion
and wheel house, decrease the pressure. But the
force of water must be made strong occasionally by
pressing the end of the hose.
NOTE:
Be sure to keep the hose at least 10 cm (3.9 in)
from the vehicle.
Check the following areas:
• Front window and body framework mating por-
tion
• Door mating portions
• Glass mating portions
• Rear quarter window mating portions
• Rear window and body framework mating portion
• Around roof drips
PI-12
(B)
PM-00070

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents