Setting the individual temperature

If the currently active setpoint temperature for the room temperature con-
troller is not suitable (temperature is too warm or too cool) the current tem-
perature step can be modified until the next switching point.
1. Press S.
✓ The currently set individual temperature
flashes.
2. Set the desired temperature with + or -.
3. Confirm the set temperature with S.
✓ The room temperature controller returns to
the normal display and regulates the set indi-
vidual temperature until the next switching
time in the time program. As long as the indi-
vidual temperature is used for control, no
operating mode (Comfort, Lowering, Anti-
freeze) is displayed, since none of the tem-
peratures stored there is valid.
i
Note
If the S button is not pressed, the display returns to the normal display
again after 5 seconds. Any changes to the setpoint temperature are not
accepted in this case.
Reactivating the time program
1. P reactivates the time program.
6

Settings in the program menu

You can change the following settings in the program menu:
• Date and time (Uhr menu item)
• Temperature steps (tEmP menu item)
• Time program (ProG menu item)
• Holiday function (UrLb menu item)
• Anti-freeze function (FrSt menu item)
• Selecting the operating mode (ModE menu item)

Starting the program menu

1. Press P at least 5 seconds long in the normal display.
2. Select the desired menu item with + or -.
The adjacent example shows the first menu
item, the time.
3. Select the desired menu item with S.