Modifying the time program – ProG menu item
In the ProG menu item the switching times of the room temperature con-
troller are set or modified. A maximum of 32 switching times are available.
Each switching time specifies a point within a week at which a change
between the comfort and lowering modes takes place.
The time program is only used in the Heating operating mode. In Cooling
operating mode, the time program is interrupted and the cooling tempera-
ture is used as the setpoint.
The following time program is programmed at the factory:
Weekdays
Period
Monday - Friday
6:00 -22:00 comfort temperature
Saturday, Sunday
6:00 -23:00 comfort temperature
These switching times can be modified or extended freely (in 10 minute
steps).
Viewing the switching times
1. Press P for 5 seconds.
2. Press + several times to switch from Uhr to ProG and confirm with
S.
✓ The first switching time is displayed.
3. Set the further switching times with + or -.
✓ The switching times are displayed chronolog-
ically, beginning at Monday 0.00 hours,
increasing to a maximum of Sunday 23.50.
✓ An empty switching time "--:--" is displayed at
the end of the list if one is still available.

Modifying the switching time

1. Press P for 5 seconds.
2. Press + several times to switch from Uhr to ProG and confirm with
S.
3. Select the switching time to be modified with + or - and confirm with
S.
✓ The switching time is opened for editing, the
hour display flashes.
4. Set the hours with + or - and confirm with
S.
5. Enter all further data in the same manner:
• Minutes
• Day – here the weekdays are initially displayed,
and then the groupings Sa-Su, Mo-Fr, Mo-Sa and Mo-Su.
• Comfort or lowering temperature
i
Grouping days
If a grouping of days is selected, a separate program point with the speci-
fied time and the temperature step is created for each selected day of the
group.
Renewed editing of the entire grouping is not possible - only the individual
program items can be edited.
6. Confirm each time with S.
✓ After the last confirmation with S the modified switching time is saved
and the chronologically next switching time is displayed.