Table of contents Normal view in the display ..............3 Basic operation of the room temperature controller ......3 The individual displays and buttons ..........3 On these instructions ................4 How the room temperature controller functions ........4 Starting up the room temperature controller ...........4 Prolonging the heating phase (party function).........5 Terminating the party function............5 Changing over to the lowering temperature (economy button)....5...
Normal view in the display The individual displays and buttons The current weekday is displayed here. Symbol for the "Time program" operating mode. Symbol for the "Comfort temperature" operating mode. Symbol for the "Lowering temperature" operating mode. Symbol for the "Anti-freeze temperature" operating mode. The respective current operating mode is indicated here by means of triangles.
On these instructions Starting up the room temperature controller The following symbols and marks are used in these instructions: When the room temperature controller is switched on for the first time as well as after long deactivation periods, e.g. after a power failure, the room 1.
Prolonging the heating phase (party function) Changing over to the lowering temperature (economy button) If necessary, you can extend or activate the comfort temperature – the so- You can change over to the lowering temperature for brief or long-term called party function. This extension applies only once. After the periods of absence by means of the economy button.
Setting the individual temperature Locking buttons You can set an individual temperature if the currently set temperature of To prevent accidental or unauthorised operation of the room temperature the time program does not appear to be suitable. controller, you can activate the button locking function in the normal view.
Settings in the program menu ✓ The hour display flashes. 2. Press the + or - button until the desired You can change the following settings in the so-called program menu: hour has been set. • Date and time (Uhr menu item) •...
Modifying the temperature steps – tEMP menu item Aborting modifications to the temperature steps: You can modify the following temperature steps in the tEMP menu item. 1. Press the P button in order to abort setting the temperature steps. • Comfort temperature (default 21.0 °C) ✓...
Page 9
Deleting the switching time ✓ An empty switching time is offered at the end of the list if at least one switching 1. Go in the program menu to the ProG menu item (see Page 7). time is still available. 2.
Page 10
Inserting a new switching time Aborting the settings at the time program You can abort the modifications at the time program if no switching time 1. Go in the program menu to the ProG is opened for processing. menu item (see Page 7). 1.
Setting the holiday program – UrLb menu item ✓ The display changes to the holiday end. A holiday program is available in the UrLb menu item. You set the starting ✓ The month is displayed flashing. date and end date of your absence here. During this period the system 7.
Activating/deactivating the anti-freeze function – ✓ After the anti-freeze function has been deactivated, the room FrSt menu item temperature controller returns to continuous Lowering mode. You can only permanently activate the anti-freeze function here. Proceed as follows in order to return to the normal time program: 1.
Page 13
We provide a warranty as provided for by law. Please send the unit postage free with a description of the defect to our central customer service via your specialised dealer: Gira Giersiepen GmbH & Co. KG Service Center Dahlienstraße 12...
Page 14
Mounting Instructions and Commissioning for the Electrician Room temperature controller with clock 0389 ..
On these instructions The following symbols and marks are used in these instructions: 1. Action instructions are numbered consecutively. ✓ Results of actions are identified by this check mark. • Enumerations are identified by this point. Note! Information on the economical use of the room temperature controller is identified by this sign.
Installation • Lay the base sensor of the room temperature controller in a sensor conduit. If an open sensor conduit is to be used, close it with a plug so that tile bonding agent or cast plaster cannot ingress into the sensor Installation and safety instructions conduit, causing the sensor to be damaged.
Ext. sensor (optional) Load Safety function The top unit of the room temperature controller is protected against unintentional placing on the underplaster unit of a Gira blinds control system. When used incorrectly the room temperature controller displays the text FAIL flashing.
Start-up (basic setting) r (ramp) Gradient of the heating optimisation in minutes per Kelvin [min/K] Important information on changes in the parameter menu S (Summertime) Specification which summertime regulation (Central European or GB) is to be used for Changes in this menu should only be carried out by qualified persons calculation since incorrect settings may result in proper control operation no longer being possible.
Normal display (n) Differential gap (d) This parameter is used to select the normal display of the controlling This parameter defines the differential gap (hysteresis) of the controlling device. This information is always displayed on the display whenever no function. menu has been selected and no holiday settings are active.
Minimum ON period (t) Gradient for heating optimisation (r) In order to prevent frequent relay switching, this parameter can be used The current gradient which is used to calculate the derivative action time to specify the minimum ON period. This period specifies the minimum can be checked under this menu item.
Accuracy (U) Resetting all the settings (Reset) Here a correction value is entered at the factory, which ensures the You can delete all the parameter settings and programming and reset the greatest possible precision of the clock function. device to the standard factory values: The value represents the correction amount in seconds per day and 1.
Technical data Electrical endurance Min. 5 x 10 switching cycles Type GIRA room temperature controller Minimum ON period 20 s to 500 s Temperature ranges + 10 ... + 40 °C (comfort and Increment 10 s lowering temperature) + 5 ... + 15 °C...